Weight dry: 500 kg (1102 lb); wet: 520 kg (1146 lb).
Lubrication System
Oil filter type: spin-on, full flow.
Total oil capacity: 8.0 l (2.1 US gal).
Oil pan capacity: 7.0 l (1.8 US gal).
Oil type: API CC/SE.
Cooling method: water.
Performance 50 Hz / 60 Hz
Engine speed: 1500 rpm at 50 Hz, 1800 rpm at 60 Hz.
Gross engine power standby: 103.0 kW (138.0 hp) at 50 Hz, 117.5 kW (158.0 hp) at 60 Hz.
Gross engine power prime: 93.6 kW (126.0 hp) at 50 Hz, 106.8 kW (143.0 hp) at 60 Hz.
BMEP prime: 1702.0 kPa (246.9 psi) at 50 Hz, 1619.0 kPa (234.8 psi) at 60 Hz.
BMEP standby: 1873.0 kPa (271.7 psi) at 50 Hz, 1781.0 kPa (258.3 psi) at 60 Hz.
Regenerative power: 8.2 kW at 50 Hz, 13.8 kW at 60 Hz.
Fuel System
Fuel filter type: replaceable element.
Recommended fuel: class A2 diesel.
Fuel consumption prime at 50 Hz: 24.1 l/hr (6.4 US gal/hr) at 110% load, 21.9 l/hr (5.8 US gal/hr) at 100% load, 16.6 l/hr (4.4 US gal/hr) at 75% load, 11.7 l/hr (3.1 US gal/hr) at 50% load.
Fuel consumption prime at 60 Hz: 29.3 l/hr (7.7 US gal/hr) at 110% load, 26.3 l/hr (6.9 US gal/hr) at 100% load, 19.9 l/hr (5.3 US gal/hr) at 75% load, 14.2 l/hr (3.8 US gal/hr) at 50% load.
Fuel consumption standby at 50 Hz: 24.1 l/hr (6.4 US gal/hr) at 100% load, 18.2 l/hr (4.8 US gal/hr) at 75% load, 12.6 l/hr (3.3 US gal/hr) at 50% load.
Fuel consumption standby at 60 Hz: 29.3 l/hr (7.7 US gal/hr) at 100% load, 21.9 l/hr (5.8 US gal/hr) at 75% load, 15.4 l/hr (4.1 US gal/hr) at 50% load.
Air System 50 Hz / 60 Hz
Air filter type: replaceable element.
Combustion air flow standby: 6.3 m³/min (221 cfm) at 50 Hz, 7.8 m³/min (275 cfm) at 60 Hz.
Combustion air flow prime: 6.0 m³/min (212 cfm) at 50 Hz, 7.8 m³/min (274 cfm) at 60 Hz.
Maximum combustion air intake restriction: 8.0 kPa (32.1 in H₂O) at both frequencies.
Radiator cooling air flow: 187.8 m³/min (6632 cfm) at 50 Hz, 244.2 m³/min (8624 cfm) at 60 Hz.
External restriction to cooling air flow: 125 Pa (0.5 in H₂O) at both frequencies.
Cooling System 50 Hz / 60 Hz
Cooling system capacity: 17.5 l (4.6 US gal) at both frequencies.
Water pump type: centrifugal.
Heat rejected to water and lube oil standby: 50.7 kW (2883 Btu/min) at 50 Hz, 64.0 kW (3640 Btu/min) at 60 Hz.
Heat rejected to water and lube oil prime: 46.1 kW (2622 Btu/min) at 50 Hz, 57.7 kW (3281 Btu/min) at 60 Hz.
Heat radiation to room standby: 7.5 kW (427 Btu/min) at 50 Hz, 9.4 kW (535 Btu/min) at 60 Hz.
Heat radiation to room prime: 6.8 kW (387 Btu/min) at 50 Hz, 8.5 kW (483 Btu/min) at 60 Hz.
Radiator fan load: 2.8 kW (3.8 hp) at 50 Hz, 4.8 kW (6.4 hp) at 60 Hz.
Exhaust System 50 Hz / 60 Hz
Silencer type: industrial.
Silencer noise reduction: SD50 (1).
Pressure drop across silencer system: 2.10 kPa (0.620 in Hg) at 50 Hz, 3.56 kPa (1.051 in Hg) at 60 Hz.
Silencer noise reduction level: 22 dB at 50 Hz, 17 dB at 60 Hz.
Exhaust back pressure: 18.0 kPa (5.3 in Hg) at 50 Hz, 15.0 kPa (4.4 in Hg) at 60 Hz.
Exhaust gas flow standby: 16.3 m³/min (576 cfm) at 50 Hz, 20.4 m³/min (720 cfm) at 60 Hz.
Exhaust gas flow prime: 15.2 m³/min (537 cfm) at 50 Hz, 18.4 m³/min (650 cfm) at 60 Hz.
Exhaust gas temperature standby: 543 °C (1009 °F) at 50 Hz, 574 °C (1065 °F) at 60 Hz.
Maximum allowable back pressure: 514 (957) at 50 Hz, 517 (963) at 60 Hz.
Alternator Performance Data
Motor starting capability: 187 kVA at 415/240 V, 176 kVA at 400/230 V, 160 kVA at 380/220 V, 208 kVA at 220/127 V, 206 kVA at 480/277 V, 136 kVA at 380/220 V, 160 kVA at 240/120 V, 149 kVA at 230/115 V, 177 kVA at 440/254 V.
Short circuit capacity: 300% for all voltage configurations.
Reactances per unit: Xd 3.200, X'd 0.120, X''d 0.074 at 415/240 V; Xd 3.440, X'd 0.130, X''d 0.080 at 400/230 V; Xd 3.810, X'd 0.150, X''d 0.089 at 380/220 V; Xd 2.840, X'd 0.110, X''d 0.066 at 220/127 V; Xd 3.240, X'd 0.130, X''d 0.075 at 480/277 V; Xd 5.080, X'd 0.200, X''d 0.118 at 380/220 V; Xd 4.310, X'd 0.170, X''d 0.100 at 240/120 V; Xd 4.660, X'd 0.180, X''d 0.108 at 230/115 V; Xd 3.850, X'd 0.150, X''d 0.090 at 440/254 V.
Reactances shown are applicable to standby ratings.
Motor starting capability based on 30% voltage dip at 0.6 power factor.
Short circuit capacity with optional permanent magnet generator or AREP excitation.
Alternator Technical Data
Manufacturer: OLYMPIAN.
Model: LL3014B.
Number of bearings: 1.
Insulation class: H.
Winding pitch code: 2/3 - 6.
Wires: 12.
Ingress protection rating: IP23.
Excitation system
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.