Test method: ATSM D 2859: 2006 – result: #1 (pass).
Minimum 25 mm must separate char from edge of flattering (EA): 6.
Note: This standard test method was applied by the client's request.
Test method: FMVSS 302 – result: #1 (pass).
As received – damaged length (mm): 0 0 0 0 0.
Burning time (s): 0 0 0 0 0.
Burn rate (mm/min): SE SE SE SE SE (self-extinguishing).
Conclusion: pass. Requirement: ≤ 102 mm/min.
Test condition: (16 ~ 27) °C, (55 ± 5) % R.H., 24 h.
Test method: UL 94-HBF (2012) – result: #1 (pass).
Did flame reach 25 mm gauge mark: yes yes yes yes yes.
Burn distance after 25 mm gauge mark (mm): 71 45 72 56 63.
Burning duration after 25 mm gauge marks (s): 132 96 133 116 125.
Burning rate (mm/min): 32 28 32 29 30.
Conclusion: Based upon the results, the submitted sample meets performance requirements as stated in UL94-HBF use in its original state.
Acceptance criteria: Not have any specimens with a burning rate exceeding 40 mm per minute over a 100 mm span, or have each specimen cease to burn before flaming or glowing reaches the 125 mm gauge mark.