Mitsubishi, Westinghouse, GE, Wartsila, Power Plants, Turbines, Engines

Description

  1. Overview
    1. 1352 MW 50 Hz Mitsubishi gas turbine
    2. 8 units 146 MW each Mitsubishi Westinghouse 701 DA 50 Hz
    3. Installed and commissioned in 1990-1993
    4. 8 x air-cooled generators, manufactured by Brush
    5. Power rating of 146 MW at 15 °C with a maximum capacity of 169 MW
    6. Heat rate of 9,930 BTU/kWh (LHV) with exhaust gas temperature of 543 °C
    7. Main fuel is natural gas, capable of burning propane and naphtha as backup fuels
    8. Operating gas pressure: 28.3-29.7 barg on NG, 16.5-18.25 barg on propane
    9. Steam injection for NOx emissions control or power augmentation
    10. Complete delivery possible: disassembly, installation, commissioning and start up
  2. 768 MW Frame 9FA CC, New Natural Gas Power Plant
    1. 2 units a 384 MW each 50 Hz power blocks
    2. 2 x GE 9FA+E 240 MW, T/GS, (2) CMI HRSGs
    3. 2 x 144 MW Alstom STGs
    4. Turbine generators: 2 x GE type 324
    5. Rating: 261.65 MW, Hz: 50
    6. STGs 2 x Alstom, Germany
    7. Model: HD1CK + MDG 160/NE37AA
    8. Rating: 144.199 MW
    9. Type: full condensing, single shaft, two casing
    10. STG generators: 2 x Alstom
    11. Rating: 141.28 MW, Hz: 50
  3. 452 MW 50 Hz Dual Fuel Gas Turbine
    1. 4 x 113 MW frame 9E dual fuel
    2. Year 1992, refurbished 2002-2005
    3. Manufacturer: Nuovo Pignone (General Electric)
    4. Turbine type frame 9 model PG 9161 E
    5. Manufactured 1994 + 1995
    6. Fuel: natural gas, fuel oil
    7. 4 x Ansaldo generators 140 MVA
    8. Rated voltage 15,000 V ± 5%
    9. Hertz 50, RPM 3000, power factor 0.9
  4. 132 MW Gas Turbine (HFO) + 1 Steam Turbine
    1. Gas turbine: Westinghouse W251B11
    2. Power: gas turbine 2 x 48,000 kW (rated capacity), output 42.5 MW when running on HFO
    3. Steam turbine: 1 x 36,000 kW (rated capacity)
    4. Running on HFO (till stop of operation) and includes all related HFO treatment auxiliaries, and can be converted back to gas operation
    5. Incl. related auxiliaries: control panels / switchgear (LV / HV (11 kV)) / fuel treatment / station transformers
    6. Commissioned in May 2000 and stopped operation in August 2007
    7. Last maintenance was carried out in 2006 / 2007
  5. 52 MW 50 Hz Dual Fuel Engines
    1. 6 x 8.7 MW Wartsila W20V34DF
    2. Auxiliaries and related services
    3. 8.7 MW each, 11 kV, 50 Hz, 750 RPM, IP23, F/B
    4. 4 stroke engines, dual fuel, diesel or gas, trunk piston, turbocharged and intercooled
  6. 750 MW 3 x 250 MW 50/60 Hz Coal Fired Plant Complete
    1. Year 1993, total operational hours 40,000 hours
    2. Can be converted to 60 Hz
  7. 330 MW 50 Hz Coal Fired Steam Power Plant
    1. All equipment is in excellent condition and professionally preserved
  8. 300 MW 60 Hz (50 Hz) New Coal-Biomass Plant
    1. This new plant can be converted to 50 Hz for extra fee
  9. 120 MW 50 Hz Coal Fired Power Plant
    1. Manufacturer: Siemens-Schuckertwerke AG
    2. Type: condensing-extraction
    3. Speed: 3000 U/min
    4. Power: min. 125 MW, max. 140 MW
    5. Pressure: 185 bar, temperature: 530 °C
    6. Frequency: 48.5-51.5 Hz
    7. Year: 1967
    8. Boiler: Babcock
  10. 18 MW 50 Hz Coal Fired Power Plant
    1. Installed in 2005 and completed in 2006, put into formal operation in 2006
    2. 2 x 75 t/h CFB boilers + 1 x 15 MW extraction condensing steam turbine + 1 x 18 MW generator
    3. Each boiler is equipped with 2 sets of water cooling rolling type slag coolers
    4. Boiler is equipped with fuel supply system (oil tank, oil pump and ignition device)
    5. Extraction condensing turbine unit, C15-4.9/0.98 (rated output 15 MW, max. output 18 MW)
  11. 130 MW 60 Hz Wartsila 18V32 HFO Power Plant
    1. Break down in 93 MW (38.4 MW + 54.6 MW) HFO 60 Hz
    2. Installation and commissioning for business running at 2005
    3. Total running hours less than 12,000 hrs
    4. Base on operation manual engine had overhauled one time during the 6,000 hrs of running interval, so far approach to the 12,000 hrs of running (i.e. the new owner shall carry out the 12,000 hrs interval overhaul very soon)
  12. 120 MW 60 Hz GE Frame 6 Dual Fuel HFO Gas
    1. Manufacturer: General Electric 6 x MS5001N
    2. 6 x 19,550 kW (base) - 22,880 kW (peak)
    3. Fuel configuration: natural gas / fuel oil
    4. Starting system: GE electric motor 400 HP
    5. Average operating hours: 14,000 lifetime
    6. Average number of starts: 3,500 lifetime
    7. Acoustic enclosures: yes
    8. Generator General Electric model: 161X684
    9. Hertz: 60, KVA: 23,000 (base) - 26,200 (peak)
  13. 40 MW 50 Hz Dual Fuel Sulzer Power Plant
    1. 4 x engine type Sulzer 16ZAV40S
    2. Year of manufacturing 1991
    3. Output 10,560 kW, RPM 500
    4. Alternator GEC Alstom, year and place 1992 France
    5. Apparent power 14,000 KVA
    6. Rated voltage 11,000 V, speed 500 RPM
    7. Dual fuel gas kit multi point gas injection by Sogav
    8. 4 HFO separators Alfa Laval
    9. 11 kV MV breakers GEC Alsthom, 9 in number
    10. Natural gas skid Emerson, year 2011
    11. Natural gas heater Thuba Switzerland, year 2011
    12. Fuel handling pumps Borger Germany, year 2007
  14. 25.4 MW 50 Hz Deutz HFO
    1. 4 units 6.35 MW each Deutz type: 16M640
    2. Rated output: 4 units x 6,350 kW
    3. Year: 1992, hours: 1# 22,672, 2# 31,930, 3# 30,695, 4# 32,620
    4. Turbocharger 4, manufacture: ABB type: VTR354-11
    5. Alternators 4, manufacture: Siemens type: 1DK 4735-3BE 03-Z
  15. 10 x 1.6 MW 50 Hz Cat D3516 Diesel
    1. 10 x 1.6 MW 50 Hz Caterpillar D3516B diesel oil packages
    2. Manufacturer: Caterpillar D 3516 B
    3. Power: 1,600 ekW / 2,000 KVA
    4. Voltage: 50 Hz / 400 V prime
    5. Year: 2012
  16. 13 MW 50 Hz Dual Fuel (HFO, Diesel)
    1. 2 x 6.5 MW 50 Hz Wartsila 18V32LN
    2. Total engine running hours 64,451 as on 27.6.2013
    3. Fuel used: FO, HFO, LDO and HSD
    4. Alternator type: AMG0900XS08DSE
    5. Year: 2003, output: 7,825 KVA
    6. Phase: 3, voltage: 6,600 V
    7. Duty: S1, frequency: 50 Hz
  17. 1 MW 50 Hz Diesel Engine Package MTU
    1. Manufacturer: MTU 12 V 396 TB 34
    2. Fuel: diesel oil
    3. Power: 1 MW
    4. Year of manufacturer: 1996
    5. Running hours: 139
    6. Voltage: 10 kV / 50 Hz
    7. Scope of supply: complete container, including PLC and oil tank
  18. 15.6 MW 60 Hz (50 Hz) Solar Taurus 60 Dual Fuel
    1. 3 x 5,200 kW landfill, natural gas GTG, 60 Hz, 4,160