Cogeneration group that transforms chemical energy of a fuel (diesel, gas, or biogas) into mechanical rotation energy for the electric generator and partially into thermal energy from residual exhaust gases and fluids.
Mechanical energy transmitted to the electric generator is transformed into electrical energy.
Thermal energy is recovered from heat exchangers via thermal exchanges on predetermined fluid vectors such as water, steam, or air to desired temperatures.
Management and control are automatic, performed by a microprocessor programmed by the manufacturer.
The microprocessor manages all alarm and lock systems required to maintain component condition and operator safety.
Normal operation does not require on-site personnel.
All machines used are conform to directive 89/392 CE.
Engine And Generator
Engine brand: Guascor, type FGLD 480/80.
Electric generator brand: Leroy Somer, type LSA49.1 L9.
Components And Accessories
Electric pumps water motor circuit/secondary/inter-cooler brand Calpeda, type varie.
Plate heat exchanger water-water brand Cipriani, type SV300M12/085/304/E/AFL.
Flow meter water brand Endress Hauser, type Promag 30 F DN 80.
Controller of calculating thermal energy in hot water brand Raab Karcher, type T 25.
Thermostats regulating Euwel brand, type EWPC 901/902.
Adjustment thermostat brand Imit, type TC2.
Clock programmer brand ABB, type DTT1/1.
Stabilized power supply three-phase brand type EZM.
Brand ABB Sace, type Isomax DX series S7 1600A.
Enel protection interface DV 601 brand Thytronlc, type DMA 100.
Protection interface electric generator DV 602 brand Thytronlc, type DMA 200.
Protection electric generator 64 brand Thytronlc, type RMT/6.
Protection electric generator brand Lovato, type DRV3.
Protection electric generator brand Thytronlc, type 67R.
Card exchange 'zero' with network brand Woodward, type Process-Controll.
Synchronizer brand Woodward SPM type.
Control board laps/engine and power brand Woodward, type 2301.
Manual programmer (PLC) brand GE Fanuc, type Logicmaster 90-30.
Programmers manual alarms viewer brand T-Une, type TCPOLR-04.
Manual control controller temperatures cylinders brand Tecsystem, type MM453.
Documentation And Certificates
Instruction manual and technical specifications of the electrical panel.
CE machines certificate.
CE declaration group engine/alternator brand Guascor way FGLD 480/80.
Framework test electrical power and control report.
Flow meter water brand and H way Promag 30 F DN 80.