Mitsubishi, 701 DA, 1990, 1352 MW Gas Turbine Power Plant, 50 Hz, 8 Units x 146 MW

Description

  1. Overview
    1. Eight units, each 146 mw, mitsubishi westinghouse 701 da 50 hz
    2. Installed between 1990 and 1993
    3. Complete delivery possible: disassembly, installation, commissioning and start up
    4. Will be delivered with new control system
  2. Generator Specifications
    1. Eight air-cooled generators, manufactured by brush
    2. Power rating of 146 mw at 15 °c with a maximum capacity of 169 mw
    3. Heat rate of 9,930 btu/kwh (lhv) with exhaust gas temperature of 543 °c
  3. Fuel System
    1. Main fuel is natural gas, capable of burning propane and naphtha as backup fuels
    2. Operating gas pressure: 28.3 - 29.7 barg on ng, 16.5 – 18.25 barg on propane
    3. Steam injection for nox emissions control or power augmentation