Turbine: Brown Boveri (BBC) double extraction back-pressure turbine, year 1982
Generator: Brown Boveri (BBC) type WX14L-032-LLT, year 1982
Exciter: Brown Boveri (BBC) brushless exciter type WBT 74/188-22 AO, year 1981
Permanent magnet generator type WPE 35-9-4R20
Voltage regulator: Brown Boveri (BBC) Unitrol, year 1981
Control systems: Brown Boveri (BBC) / Bently Nevada, year 1981 and newer
Lubrication systems: Rexroth / Alfa Laval / others, year 1982 and newer
Switchgear: GE, complete
Battery pack, UPS, and motor control center: GE, complete
Turbine Specifications
Power: 21.4 MW
Current inlet pressure/temperature: 1450 psig / 950°F
Current extraction/exhaust pressure: 400 - 150 psig / 50 psig
Max inlet flow: 330,000 lbs/h
RPM: 3600
Weight: N/A
Running time: 0 hours since overhaul in June 2012
Overhaul dates: majors in June 2012, 2004, 1998
Generator Specifications
Power: 24 MVA
Power factor: 0.85
RPM: 3600 (direct coupling)
Voltage/phase/Hz: 13.8 kV / 3 / 60
Current: 1004 A
Weight: 80,770 lbs
Cooling: Internal air-cooled from under generator with water cooling system from Perfex
Total loss dissipation rated at 540 kW
Exciter Specifications
Rated output / ceiling output (max 10 s): P = 151 kW / 268 kW, U = 165 V / 220 V, I = 915 A / 1220 A
Field current (Ifw): 12.5 A / 19 A
Field voltage (Ufw): 57 V / 87 V
RPM: 3600
Permanent Magnet Generator Specifications
Type: WPE 35-9-4R20
Output (P): 8.6 kVA / 11 kVA
Power factor (cos φ): 0.5 / 0.8
Frequency (F): 120 Hz
Voltage (V): 407 V
Current (U): 12.2 A / 15.6 A
RPM: 3600
Voltage Regulator Panel Content
Dual channel VR: Unitrol K16008
Unitrol 3310-3313
Integrator: Unitrol 0008
Limitation regulator: Unitrol 0021
Pulse regulator: Unitrol 0510
Load angle limiter: Unitrol 1041a
Limitation unity: Unitrol K3001
Supervision for rotary rectifiers: type URGA
Control Systems Functions
The electro-hydraulic control and safety system opens or closes the various control valves as necessary to control speed and load, frequency, extraction pressures, and back-pressure in various combinations, depending on the desired performance mode.
The system also provides necessary safety functions, preventing turbine overspeed, overpressure in HP, IP, and LP sections, and other hazardous conditions.
Panel content includes display for pressure and temperature of inlet, extraction, and exhaust steam.
Vibration monitor: Bently Nevada 3500
Lubrication Systems Functions
The oil supply system supplies oil at a controlled temperature and pressure and directs its flow to the bearings of the turbine, generator, and exciter.
In addition, the system supplies oil to the four main bearings to lift the shaft during starting, stopping, and turning gear operation, and to cool the control fluid.
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.