Description Overview 28 MW steam turbine power plant Two 14 MW Stal Laval steam turbines: one operating at high pressure and the other at low pressure Complete plant in good condition, well maintained, and has provided reliable operation since installation Specifications 50 Hz 5250 V Turbine 1 (High Pressure) Normal steam pressure: 107 barg Maximum steam pressure: 127 barg Steam temperature before valve: normal 530 °C, maximum 540 °C Extraction pressure: 45 barg Back pressure: 25 barg Turbine 2 (Low Pressure) Normal steam pressure: 25 barg Maximum steam pressure: 40 barg Steam temperature before valve: normal 350 °C, maximum 425 °C Extraction pressure: 6.2 barg Back pressure: 1.8 barg Condition Good condition Well maintained Reliable operation since installation