Description Overview 6 MW Stal Laval steam turbine Originally built for 3 bar back pressure and delivered 11 MW Rebuilt in 1980 to 11 bar back pressure, resulting in 6 MW output Specifications Rated power: 6 MW Generator: 13750 KVA, 6.3 KV, 50 Hz Steam conditions: 58 bara – 430 °C – 27 bara – 12.8 bara Condition and maintenance Maintained since new by Siemens / Stal-Laval in accordance with the service schedule Included New spares included in the package