Stal Laval, Back Pressure Steam Turbine, 16 MW, 36 bar, 50 Hz

Description

  1. Overview
    1. 16 MW Stal Laval back pressure steam turbine
    2. Year of manufacture: 1955
    3. Only 25,000 hours since complete overhaul of turbine and generator
    4. All magnetism equipment and vibration equipment new in 1996
    5. Plant is in excellent condition
  2. Specifications
    1. Working pressure: 36 bar
    2. Maximum pressure: 42 bar
    3. Extraction: 11.8 bara
    4. Backpressure: 4.7 bara
    5. Steam flow: 158 T/h
    6. Extraction flow: 30 T/h
    7. Temperature: 450 °C
    8. Voltage: 6300 volt
    9. Frequency: 50 Hz
  3. Condition
    1. Excellent condition
    2. Complete overhaul of turbine and generator with only 25,000 hours of operation since
    3. All magnetism equipment and vibration equipment replaced in 1996
  4. Included
    1. Plant can be offered dismantled and shipped to port