NovaStar, GL172, Air Permeability Tester, 10,000 Pa Pressure, Touch Screen Control (New)

Description

  1. Overview
    1. S model: manual replacement of the orifice plate
    2. A model: automatic replacement of the orifice plate
    3. Used to test the air permeability of various woven fabrics, knitted fabrics, nonwoven fabrics, industrial filter materials, etc.
  2. Standards
    1. ASTM D737, ASTM D3574, AFNOR G07-111, BS 5636, DIN 53,887, EDANA 140.1, EN ISO 7,231, EN ISO 9,237, JIS L1096-A, TAPPI T251 and so on
  3. Features
    1. More excellent anti-jamming, more excellent stability, more rapid data transference speed
    2. Adopt microcomputer control system, branded high accuracy pressure sensor, digital feedback and adjust air volume
    3. Automatic follow, measure and display pressure difference of each point with high stability and repeatability
    4. All nozzles have been calibrated by-point in full testing range to let test data more accuracy
    5. All test data is displayed by large high-definition large color touch screen displayer, no need to calculate test result by hands
    6. Automatic converse air permeability rate and air permeability volume to improve test efficiency
    7. Large touch screen displayer and controller
    8. Equipped with inner printer
    9. Adopt micro-computer control, insure the test data accuracy and test data can be saved and processed automatically
    10. Special designed sample holder accomplish test in box and ensure the yarn without slip
    11. Equipped with the inner printer, test report can be printed anywhere
    12. Testing procedure can be set conveniently by the inner control panel
    13. With the function of saving data when power-down
    14. Professional software support to output results to PC
  4. Technical Parameters
    1. Working pattern: high precision imported pressure sensor, touch screen control, printing and testing report
    2. Pressure volume: 10,000 Pa
    3. Specimen thickness: ≤12 mm
    4. Measuring accuracy: ≤±2%
    5. Test area/diameter: 20 cm², diameter 70 mm (equal to 38 cm²) optional: 50 cm², 100 cm², 5 cm², diameter 50 mm
    6. Units: total 8 units to can be freely switched: mm/s, L/m²
    7. Orifice plate: 8 pcs (diameter 0.5 mm, diameter 1.0 mm, diameter 1.5 mm, diameter 2.5 mm, diameter 4.5 mm, diameter 8.0 mm, diameter 14.5 mm, diameter 26 mm)
    8. Calibration: unique calibration board
    9. Permeability ratio range: 0.2-11000 mm/s (L/m²)
    10. External dimensions: 700 x 1000 x 1000 mm
    11. Gross weight: 100 kg