Siemens, v 94.3, Combined Cycle Power Plant, 2007

Description

  1. Overview
    1. Listing of multiple gas turbine and combined cycle power plant configurations, including Siemens V 94.3, GE LM series, and Wartsila gensets.
    2. All plants are complete with associated steam turbines, boilers, or HRSGs as specified.
  2. Siemens V 94.3 Combined Cycle Plants
    1. 1200 MW plant: 3 units each 400 MW, 3 x Siemens V 94.3 plus steam turbines and boilers, built 2007, salt water cooling.
    2. 1200 MW plant: 3 units each 400 MW, 3 x Siemens V 94.3 plus steam turbines and boilers, built 2005, river water cooling.
    3. 800 MW plant: 2 units each 400 MW, 2 x Siemens V 94.3 plus steam turbines and boilers, built 2008, salt water cooling.
    4. 800 MW plant: 2 units each 400 MW, 2 x Siemens V 94.3 plus steam turbines and boilers, built 2011, salt water cooling.
    5. 800 MW plant: 2 units each 400 MW, 2 x Siemens V 94.3 plus steam turbines and boilers, built 2008, river water cooling.
    6. 400 MW plant: 1 unit 400 MW, 1 x Siemens V 94.3 plus steam turbine and boiler, built 2011, salt water cooling.
    7. 400 MW plant: 1 unit 400 MW, 1 x Siemens V 94.3 plus steam turbine and boiler, built 2008, salt water cooling.
    8. 400 MW plant: 1 unit 400 MW, 1 x Siemens V 94.3 plus steam turbine and boiler, built 2008, river water cooling.
    9. 400 MW plant: 1 unit 400 MW, 1 x Siemens V 94.3 plus steam turbine and boiler, built 2011, river water cooling.
  3. GE and Other Gas Turbine Plants
    1. 250 MW power barge: 4 units gas turbines, one steam turbine, one HRSG, GE LM 6000 and ABB, built 2003, zero hours overhauled.
    2. 188 MW plant: 3 units GE LM 6000 each 49.48 MW, plus one Siemens steam turbine, LM 6000 and Siemens, built 2005.
    3. 124 MW plant: 2 units GE Frame 6 C, each 42 MW gas turbine, dual fuel, plus 1 steam turbine and 2 HRSG, GE Frame 6 C, built 2005.
    4. 119 MW plant: GE gas turbine combined cycle power plant, consisting of 2 GE-LM gas turbines with 46.95 MW each and 1 steam turbine, GE-LM 6000, built 2004.
    5. 90 MW plant: GE gas turbine combined cycle power plant, consisting of 2 GE-LM gas turbines, 2 steam turbines and 2 HRSG, GE LM 2500 PK, LM 6000 PC and Siemens GK32/45 and ABB ATP 2-V50A, built 2010 and 1996, zero hours, overhauled.
    6. 75.3 MW plant: SGT 600, 2 units with 24.5 MW and 1 unit Solar Mars 100 with 10 MW gas turbine combined cycle power plant, Siemens SGT 600/B2 and Solar Mars 100, built 2000 and 1996 with 109,600 and 137,400 running hours.
    7. 65 MW plant: SGT 600, 1 unit with 1 unit Siemens steam turbine, SGT 600, Siemens T 6210 and Siemens VE 32, built 2000, zero hours overhauled.
    8. 62 MW plant: GE-PG 6571 gas turbine package and 1 MAN Marc 6 steam turbine, GE-PG 6571 and MAN Marc 6 C-10, built 2007, zero hours, overhauled.
    9. 55 MW plant: GE gas turbine combined cycle power plant, consisting of 1 GE-LM gas turbine, 1 steam turbine and 1 HRSG, GE LM 6000 PC and Alstom ST 3-C, built 2002, zero hours, overhauled.
    10. 35 MW plant: GE gas turbine combined cycle power plant, consisting of GE LM 2500+ gas turbine and 1 Siemens steam turbine, GE LM 2500+ and Siemens G 32/45, built 2005, zero hours, overhauled.
    11. 9.2 MW CHP plant: fuel natural gas and diesel, 50 Hz, 2 x Solar Centaur 50, T 5701, 1 steam turbine, one HRSG, built 2005 and 2008, running hours: 26,000 and 2,500.
  4. Additional Turbine Generators
    1. 90 MW plant: turbine natural gas generators, 8 units each 11.25 MW, 60 Hz, GT 10, 1,250 hours since new.
    2. 5.2 MW gas turbine package: dual fuel, 50 Hz, Solar Taurus 60 SOLO NOx, turbine from 2014, zero hour overhauled, new Siemens.
  5. Wartsila Genset Plants
    1. 140 MW plant: 13 units each 10 MW gas gensets CCPP each, in sum 280 MW available, Wartsila W 20V 34GS, built 2011, only running hours between 1,400 and 4,000.
    2. 95 MW plant: 12 units natural gas gensets, each 6 x 6.9 and 6 x 8.7 MW, cogen power plant, complete power plant, Wartsila 20V34, built 2006-2009, running hours: 22,000-44,000.
    3. 58 MW plant: 6 units gensets, each 9.7 MW, natural gas power plant, complete gensets, Wartsila 20V34, built 2012, running hours: 13,000.
    4. 58 MW plant: 6 units gensets, each 9.7 MW, natural gas power plant, complete gensets, Wartsila 20V34SG, built 2011, running hours: 1,500.
    5. 58 MW plant: 6 units gensets, each 9.7 MW, natural gas power plant, complete gensets, Wartsila 20V34SG, built 2011, running hours: 15,000.
    6. 52 MW plant: 6 units gensets, each 8.6 MW, natural gas power plant, complete gensets, Wartsila 20V34 SG HRCS, built 2005, running hours: 45,000.
    7. 48.3 MW plant: 6 units gensets, each 8.05 MW, natural gas power plant, complete gensets, Wartsila 20V34 DF, built 2011, running hours: zero, never installed.
    8. 42 MW plant: 7 units gensets, each 6 MW, natural gas power plant, complete gensets, Wartsila 16V34SG, built 2008, running hours: 25,000.