Description Overview Listing includes multiple gas turbine packages and complete power plants from various manufacturers. All units are available as used industrial equipment. Ge Lm1600 Single Marine Packages Type: 2 x LM1600. Manufacturing year: 1996 to 1999. Commissioning year: N/A. Electrical efficiency: N/A. Fuel type: Liquid. Operating hours after overhaul: N/A. 2 X Ge Lm2500 Single Marine Engine Packages Type: 2 x LM2500. Manufacturing year: 1996. Commissioning year: N/A. Electrical efficiency: N/A. Fuel type: Liquid. Operating hours after overhaul: N/A. 5 X Ge Lm2500 Single Marine Engines In Containers Type: 5 x LM2500. Manufacturing year: 1998 to 1999. Commissioning year: 1999. Electrical efficiency: N/A. Fuel type: Liquid. Operating hours after overhaul: 2 units are very very low-hour engines. 34Mw Ge Lm2500+ Combined Cycle Power Plant Type: 1 x LM2500+ DLE aeroderivative. Manufacturing year: 2003. Commissioning year: 2004. Electrical efficiency: N/A. Fuel type: N.Gas. Operating hours after overhaul: 17,000. 120Mw Ge Lm6000Pd Combined Cycle Power Plant Type: 2 x LM6000PD. Manufacturing year: 2010. Commissioning year: 2011. Electrical efficiency: 50+%. Fuel type: N.Gas. Operating hours after overhaul: 18,000. 480Mw Ge Lm6000 Complete Combined Cycle Power Plant Type: 8 x LM6000PC. Manufacturing year: N/A. Commissioning year: 1993/1999/2008/2013. Electrical efficiency: 50%. Fuel type: Dual fuel. Operating hours after overhaul: N/A. Ge Lm2500 Single Package Type: 1 x LM2500+HSPT. Manufacturing year: 2003. Commissioning year: 2004. Electrical efficiency: 38%. Fuel type: N.Gas. Operating hours after overhaul: GG: 21,000 hrs, HSPT: 20,000 hrs. 120Mw Ge Lm6000Pc Combined Cycle Power Plant Type: 2 x LM6000PC. Manufacturing year: 2004 and 2007. Commissioning year: 2006 and 2009. Electrical efficiency: 50%. Fuel type: Dual fuel. Operating hours after overhaul: 21,000 to 7,800. Ge Lm6000Pc Single Turbine Package Type: 1 x LM6000PC-NDW. Manufacturing year: 2010. Commissioning year: 2011. Electrical efficiency: 39%. Fuel type: Dual fuel. Operating hours after overhaul: 17,000. 50Mw Ge Lm6000Pc Cogen Complete Power Plant Type: 1 x LM6000PC Sprint. Manufacturing year: 2005. Commissioning year: 2006. Electrical efficiency: 39%. Fuel type: N.Gas. Operating hours after overhaul: 42,000. 60Mw Ge Lm6000Pc Complete Combined Cycle Power Plant Type: 1 x LM6000PC Sprint. Manufacturing year: 2009. Commissioning year: 2010. Electrical efficiency: 52%. Fuel type: N.Gas. Operating hours after overhaul: N/A. 63 Mw Ge Lm6000Pc Complete Combined Cycle Power Plant Type: 1 x LM6000PC. Manufacturing year: 2011. Commissioning year: 2012. Electrical efficiency: 49%. Fuel type: N.Gas. Operating hours after overhaul: N/A. 10Mw Solar Mars 100 Turbine Package Type: 1 x Solar Mars 100. Manufacturing year: 1996. Commissioning year: 1997. Electrical efficiency: 33%. Fuel type: Dual fuel. Operating hours after overhaul: 18,000. 3 X Ge Frame 6B Complete Combined Cycle Power Plants Type: 3 x Frame 6B. Manufacturing year: 1996 to 2002. Commissioning year: 1997 to 2003. Electrical efficiency: 49%. Fuel type: Dual fuel, can also burn HFO. Operating hours after overhaul: 30,000 to 45,000. 205Mw Siemens Sgt800 Combined Cycle Power Plant Type: 3 x Siemens SGT-800A. Manufacturing year: 2012. Commissioning year: 2013. Electrical efficiency: 54%. Fuel type: Dual fuel. Operating hours after overhaul: 2,500. 80Mw 2 X Ge Lm2500+ Combined Cycle Power Plant Type: 2 x LM2500+. Manufacturing year: 2002. Commissioning year: 2005. Electrical efficiency: 49%. Fuel type: Dual fuel. Operating hours after overhaul: 4,000 to 5,000. 80Mw 2 X P&W Combined Cycle Power Plants Type: 2 x P&W FT8-3. Manufacturing year: 2009. Commissioning year: 2010. Electrical efficiency: 50%. Fuel type: Dual fuel. Operating hours after overhaul: Zero. 8Mw Solar Taurus T70 Chp Plant Type: 1 x Solar Taurus T70. Manufacturing year: 2004. Commissioning year: 2005. Electrical efficiency: Not specified. Fuel type: Dual fuel. Operating hours after overhaul: 14,000. 750Kw Turboden Orc Purecycle Complete Power Plant Type: 3 x 250 kW Purecycle ORC turbines. Manufacturing year: 2011. Commissioning year: 2012. Electrical efficiency: Not specified. Fuel type: Low temperature waste heat. Operating hours after overhaul: 200. 70Mw Siemens Westinghouse Combined Cycle Power Plant Type: 1 x Westinghouse 251B11A. Manufacturing year: 1997. Commissioning year: 1999. Electrical efficiency: 50%. Fuel type: Dual fuel. Operating hours after overhaul: 5,000. 9Mw 2 X Solar Centuar 50 Ccpp Type: 2 x Solar Centuar 50 T5701. Manufacturing year: 1997. Commissioning year: 1998. Electrical efficiency: Not specified. Fuel type: Dual fuel. Operating hours after overhaul: Not specified. 260Mw Wartsila Complete Combined Cycle Power Plant Type: 28 x 20V34SG. Manufacturing year: 2007-2009-2010. Commissioning year: 2008-2010-2012. Electrical efficiency: 43%. Fuel type: N.Gas. Operating hours after overhaul: Not specified. 140Mw Wartsila Combined Cycle Power Plant Type: 13 x 20V34SG. Manufacturing year: 2011. Commissioning year: 2012. Electrical efficiency: 49%. Fuel type: N.Gas. Operating hours after overhaul: N/A. 38Mw Wartsila Combined Cycle Power Plant Type: 4 x 20V34SG. Manufacturing year: 2012. Commissioning year: 2013. Electrical efficiency: 43%. Fuel type: N.Gas. Operating hours after