GE, Siemens, Solar, Used Power Plants, 50 Hz

Description

  1. Overview
    1. Listing includes multiple gas turbine packages and complete power plants from various manufacturers.
    2. All units are available as used industrial equipment.
  2. Ge Lm1600 Single Marine Packages
    1. Type: 2 x LM1600.
    2. Manufacturing year: 1996 to 1999.
    3. Commissioning year: N/A.
    4. Electrical efficiency: N/A.
    5. Fuel type: Liquid.
    6. Operating hours after overhaul: N/A.
  3. 2 X Ge Lm2500 Single Marine Engine Packages
    1. Type: 2 x LM2500.
    2. Manufacturing year: 1996.
    3. Commissioning year: N/A.
    4. Electrical efficiency: N/A.
    5. Fuel type: Liquid.
    6. Operating hours after overhaul: N/A.
  4. 5 X Ge Lm2500 Single Marine Engines In Containers
    1. Type: 5 x LM2500.
    2. Manufacturing year: 1998 to 1999.
    3. Commissioning year: 1999.
    4. Electrical efficiency: N/A.
    5. Fuel type: Liquid.
    6. Operating hours after overhaul: 2 units are very very low-hour engines.
  5. 34Mw Ge Lm2500+ Combined Cycle Power Plant
    1. Type: 1 x LM2500+ DLE aeroderivative.
    2. Manufacturing year: 2003.
    3. Commissioning year: 2004.
    4. Electrical efficiency: N/A.
    5. Fuel type: N.Gas.
    6. Operating hours after overhaul: 17,000.
  6. 120Mw Ge Lm6000Pd Combined Cycle Power Plant
    1. Type: 2 x LM6000PD.
    2. Manufacturing year: 2010.
    3. Commissioning year: 2011.
    4. Electrical efficiency: 50+%.
    5. Fuel type: N.Gas.
    6. Operating hours after overhaul: 18,000.
  7. 480Mw Ge Lm6000 Complete Combined Cycle Power Plant
    1. Type: 8 x LM6000PC.
    2. Manufacturing year: N/A.
    3. Commissioning year: 1993/1999/2008/2013.
    4. Electrical efficiency: 50%.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: N/A.
  8. Ge Lm2500 Single Package
    1. Type: 1 x LM2500+HSPT.
    2. Manufacturing year: 2003.
    3. Commissioning year: 2004.
    4. Electrical efficiency: 38%.
    5. Fuel type: N.Gas.
    6. Operating hours after overhaul: GG: 21,000 hrs, HSPT: 20,000 hrs.
  9. 120Mw Ge Lm6000Pc Combined Cycle Power Plant
    1. Type: 2 x LM6000PC.
    2. Manufacturing year: 2004 and 2007.
    3. Commissioning year: 2006 and 2009.
    4. Electrical efficiency: 50%.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: 21,000 to 7,800.
  10. Ge Lm6000Pc Single Turbine Package
    1. Type: 1 x LM6000PC-NDW.
    2. Manufacturing year: 2010.
    3. Commissioning year: 2011.
    4. Electrical efficiency: 39%.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: 17,000.
  11. 50Mw Ge Lm6000Pc Cogen Complete Power Plant
    1. Type: 1 x LM6000PC Sprint.
    2. Manufacturing year: 2005.
    3. Commissioning year: 2006.
    4. Electrical efficiency: 39%.
    5. Fuel type: N.Gas.
    6. Operating hours after overhaul: 42,000.
  12. 60Mw Ge Lm6000Pc Complete Combined Cycle Power Plant
    1. Type: 1 x LM6000PC Sprint.
    2. Manufacturing year: 2009.
    3. Commissioning year: 2010.
    4. Electrical efficiency: 52%.
    5. Fuel type: N.Gas.
    6. Operating hours after overhaul: N/A.
  13. 63 Mw Ge Lm6000Pc Complete Combined Cycle Power Plant
    1. Type: 1 x LM6000PC.
    2. Manufacturing year: 2011.
    3. Commissioning year: 2012.
    4. Electrical efficiency: 49%.
    5. Fuel type: N.Gas.
    6. Operating hours after overhaul: N/A.
  14. 10Mw Solar Mars 100 Turbine Package
    1. Type: 1 x Solar Mars 100.
    2. Manufacturing year: 1996.
    3. Commissioning year: 1997.
    4. Electrical efficiency: 33%.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: 18,000.
  15. 3 X Ge Frame 6B Complete Combined Cycle Power Plants
    1. Type: 3 x Frame 6B.
    2. Manufacturing year: 1996 to 2002.
    3. Commissioning year: 1997 to 2003.
    4. Electrical efficiency: 49%.
    5. Fuel type: Dual fuel, can also burn HFO.
    6. Operating hours after overhaul: 30,000 to 45,000.
  16. 205Mw Siemens Sgt800 Combined Cycle Power Plant
    1. Type: 3 x Siemens SGT-800A.
    2. Manufacturing year: 2012.
    3. Commissioning year: 2013.
    4. Electrical efficiency: 54%.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: 2,500.
  17. 80Mw 2 X Ge Lm2500+ Combined Cycle Power Plant
    1. Type: 2 x LM2500+.
    2. Manufacturing year: 2002.
    3. Commissioning year: 2005.
    4. Electrical efficiency: 49%.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: 4,000 to 5,000.
  18. 80Mw 2 X P&W Combined Cycle Power Plants
    1. Type: 2 x P&W FT8-3.
    2. Manufacturing year: 2009.
    3. Commissioning year: 2010.
    4. Electrical efficiency: 50%.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: Zero.
  19. 8Mw Solar Taurus T70 Chp Plant
    1. Type: 1 x Solar Taurus T70.
    2. Manufacturing year: 2004.
    3. Commissioning year: 2005.
    4. Electrical efficiency: Not specified.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: 14,000.
  20. 750Kw Turboden Orc Purecycle Complete Power Plant
    1. Type: 3 x 250 kW Purecycle ORC turbines.
    2. Manufacturing year: 2011.
    3. Commissioning year: 2012.
    4. Electrical efficiency: Not specified.
    5. Fuel type: Low temperature waste heat.
    6. Operating hours after overhaul: 200.
  21. 70Mw Siemens Westinghouse Combined Cycle Power Plant
    1. Type: 1 x Westinghouse 251B11A.
    2. Manufacturing year: 1997.
    3. Commissioning year: 1999.
    4. Electrical efficiency: 50%.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: 5,000.
  22. 9Mw 2 X Solar Centuar 50 Ccpp
    1. Type: 2 x Solar Centuar 50 T5701.
    2. Manufacturing year: 1997.
    3. Commissioning year: 1998.
    4. Electrical efficiency: Not specified.
    5. Fuel type: Dual fuel.
    6. Operating hours after overhaul: Not specified.
  23. 260Mw Wartsila Complete Combined Cycle Power Plant
    1. Type: 28 x 20V34SG.
    2. Manufacturing year: 2007-2009-2010.
    3. Commissioning year: 2008-2010-2012.
    4. Electrical efficiency: 43%.
    5. Fuel type: N.Gas.
    6. Operating hours after overhaul: Not specified.
  24. 140Mw Wartsila Combined Cycle Power Plant
    1. Type: 13 x 20V34SG.
    2. Manufacturing year: 2011.
    3. Commissioning year: 2012.
    4. Electrical efficiency: 49%.
    5. Fuel type: N.Gas.
    6. Operating hours after overhaul: N/A.
  25. 38Mw Wartsila Combined Cycle Power Plant
    1. Type: 4 x 20V34SG.
    2. Manufacturing year: 2012.
    3. Commissioning year: 2013.
    4. Electrical efficiency: 43%.
    5. Fuel type: N.Gas.
    6. Operating hours after