IDM Instruments, PEBT-4000, PET Bottle Pressure Tester, Touch-Screen Control, 3 Test Modes (New)

Description

  1. Overview
    1. Simple and convenient operating
    2. Touch-screen controlled
    3. Graph display of the testing curve
    4. Comprehensive report data after tests
  2. Testing Methods
    1. Ramp fill mode: Simulates the situation of PET bottle filling lines; bottles are pressurized rapidly to a pre-set initial pressure and held for 13 seconds, then continue to pressurize at 10 psi (0.69 kg/cm²) until the bottle bursts or reaches the maximum pressure or volume; pre-set parameters include initial pressure, maximum pressure, and volume expansion limit.
    2. Burst mode: Bottles are pressurized rapidly to a pre-set pressure value and held for a period of time; test parameters include burst pressure, testing time, and volume expansion limit.
    3. User-defined mode: Allows creation of a unique pressurizing curve to meet special testing requirements; users can set the pressurizing curve by stages, and the corresponding curve displays on the user interface.
  3. Features
    1. Controlled via touch screen, with RS232 data output and CND-PEBT software
    2. Applicable for different sized PET bottles
    3. Graphical real-time testing curve display
    4. Comprehensive report data
    5. Protection shield equipped near the water outlet preventing fragment block after sample burst
    6. Assembled with external filter, reducing the influence on the gauge caused by impurity in water
    7. Solenoid valve and high-pressure filter installed between water cylinder and servo valve to prevent water flowing back to servo valve from the fulfilled water cylinder in case the level sensor becomes problematic
    8. Pressure reducing valve installed on air inlet in case of over high pressure supply causing damage to the gauge
    9. High-pressure filter installed on air inlet to prevent the impurity of air supply damaging the servo valve
    10. Pressure releasing valve installed in test station to release the air quickly, protecting the machine from the rushing pressure when the bottle bursts
    11. Electrical station separated from pressurizing station to prevent water entering
    12. Filling head, copper clamp, and connector of calibration meter are durable and anti-verdigris after chromating treatment
    13. Extra door lock device assembled to protect operator during the test; with the door proximity switch, test will not start unless the door is closed, in conformity to safety protecting requirement
    14. With calibration function, configured with a pressure calibration meter and a volume calibration flask, convenient for calibrating
  4. Technical Data
    1. Operating pressure range: 0-300 psi (0-20.7 bars)
    2. Accuracy: ±3 psi (±0.2 bar)
    3. Pressure measuring units: psi, kg/cm², bars, MPa (user defined)
    4. Volume expansion measuring units: milliliters (ml)
    5. Operating temperature: 0-50°C
    6. Power supply: 110-120 or 220/240 VAC @ 50/60 Hz
    7. Expansion capability: 2 L bottle sizes supported; up to 3 L (depending on expansion percentage – 67% expansion maximum for this model)
    8. Output interface: Standard serial link
    9. Dimensions: 830 × 580 × 1600 mm (W × D × H)
    10. Weight: 120 kg
  5. Condition
    1. More information is available upon request