Deutz, TBG-604 CV-8 / TBG-620 V12K, 2MW, Gas Engine Generator Sets

Description

  1. Motors
    1. Motor 1: operating hours 59,595, type TBG-604 CV-8, motor number 604.08.010344, main maintenance at 48,000 h.
    2. Motor 2: operating hours 60,151, type TBG-604 CV-8, motor number 604.08.010345, main maintenance at 48,000 h.
    3. Motor 3: operating hours 53,645, type TBG-620 V12K, motor number 620.12.000211, main maintenance at 48,000 h.
  2. Generators
    1. Generator 1: type 1FC8409-4GB42-Z, serial number HG 097037, power 660 kVA, manufacturing date 1994.
    2. Generator 2: type 1FC8409-4GB42-Z, serial number HG 097038, power 660 kVA, manufacturing date 1994.
    3. Generator 3: type HC I734F2, serial number 96183382, power 1009.6 kW, manufacturing date 1995.
  3. Air Cooling Units
    1. Unit 1: brand Friterm, serial number 2005 1894 01 002, type FYKS 5024 C4 2,5, number of fans 8, power 16 kW, ampere X, revolution 880 D/DK, manufacturing date 2005.
    2. Unit 2: brand Friterm, serial number 2005 1894 01 001, type FYKS 5024 C4 2,5, number of fans 8, power 16 kW, ampere X, revolution 880 D/DK, manufacturing date 2005.
    3. Unit 3: type TAV 800, number of fans 6, power 1.9 to 8.3 hp, ampere 5.1 to 13.6 A, revolution 750/1500 D/DK, manufacturing date 1995.
  4. Heat Rooms
    1. Heat room 1: type WTG – GD 6.5/16, serial number 60/49979-2, manufacturing date 1994, volume 250 lt, efficiency 331 kW, operation temperature 90°C, operation pressure 10 bar.
    2. Heat room 2: type WTG – GD 6.5/16, serial number 60/49979-1, manufacturing date 1994, volume 250 lt, efficiency 331 kW, operation temperature 90°C, operation pressure 10 bar.
    3. Heat room 3: type AWKG 14, serial number 9690, manufacturing date 1996, volume 415 lt, efficiency 689 kW, operation temperature 100 to 550°C, operation pressure 10 bar.
  5. Absorption Unit
    1. Manufacturer: Alarko.
    2. Model: 16 JB 036 HW.
    3. Serial number: 16 JB.
    4. Manufacturing year: 2000.
    5. Voltage: 400.
    6. Power: 11 kW.