Coal Power Plant, 20 MW, 50Hz, 2012, 90 TPH Boiler
Scroll to zoom
100%
Description
Overview
Ro plant
Sources of water: borewell water
Amount of water from bore well: 1800 mm per day
Ro-dm plant design capacity, output: two systems are available - 52 & 34 mm / hr
Raw water and dm water storage capacity: raw water storage tank - 4000 mm, dm water storage tank - 1550 mm
Details of waste water disposal arrangement - amount of discharge, evaporation pit: waste water discharged thro' water line to gardening - green cultivation and maintaining zero discharge outside the premises
Details original design of systems & equipment: m/s doshion volia water solution ltd., ahmedabad
Primary and secondary air flow measurements: flow measuring instruments are available
Dcs output for full or max load: max 1 kw
Chimney height: 80 mtrs
Spm, sox, nox, co2, co measurements availability and measurements: all measuring instruments are available and they are to be installed, make - forbes marshall
Spares availability at the plant: see the attachment in the name of boiler spares sheet
Fuel Handling System
Belt conveyor details including width, electricals-technical data sheet: bc 1 to 1000 mm belt width, 61 m length, 9.3 kw motor, 1440 rpm; bc 2 - 1000 mm belt width, 85.6 m length, 11.19 kw motor, 1440 rpm
Slot chain conveyors details-technical data sheet: double strand pipe & fork slat type, 40 tph, 3.7 kw, chain - type / pitch - roller chain / 152.4 mm
Available fuel feeding systems into the boiler and their specifications: there are 4 nos. of screw feeders and two nos. of drag chain feeders are available
Ash removal systems details: 8 nos. of screw feeders, one no. bucket elevator & sub-mergible ash conveyors are available
Fuel shed size and construction: size of the shed - 73 x 46 x 7 mtrs; tin perforated sheets were provided in the top
Fly ash storage methods and volume: concrete fly ash silo is available and the capacity is 150 m3
Fly ash removal area available for land fill if any: already filling under progress inside the premises and some quantity sending outside for sales
Turbo Generator
Design: 20 mw, 86 ata, 515 deg.c, 4.2 kg of steam per kwh, fully condensing turbine and three bleed steam for lp heater, dea, hp heater
Avr details like auto, two channels, make etc: make- abb, two auto and one manual
110 v battery sizing: make-exide, power safe, 400 ah, 55 nos, 2v
Details of 110 v battery sizing: 400 ah, 110v
Details of metering, synchronisation and protection panels: panel type-simplex type 11kv, 20mw stg mcsp and relay panel
Acc Fans
Technical data sheet supplied by vendor: attached in acc tech. work sheet
Design temperatures: 42 deg.c
Maximum temperatures observed in the area: 45 deg.c
Max and min vacuum levels: -0.68 to -0.89
Power absorbed details: 133 kw
Ejection steam circuit details including flow, pressure and performance parameters: 11 ksc, 350 deg.c, 0.2 tph, mazda make
Esp Details
Design data like gas volume, no of fields, spm etc: 550 mm / sec, 3 fields, inlet dust conc. 5.5 gm/nm3, out let dust emission - 150 mg / m3
Electricals
Power transformer design data: make- bbl, 25000 kva, hv-132kv, lv-11000, 50hz, type of cooling-onan, phase-3 phase
Power transformer shop inspection report as well as site inspection report not available
Feed pump spares - protection sleeve, set of bearing, gland packing, set of 'o' ring & gasket, balancing & counter, balancing disc, wearing ring, returning ring: one set
Spares For Esp
Emitting electrodes: 2
Shaft insulator
Support insulator: broken
Bushing insulator: 1
Heaters
Thermostat
Geared motor rapping: 1
Hammer assembly: 3
Travelling Grate Spares
Grate clips 1": 10
Grate clips 2": 75
Tee bar: 5
Outer skid shoe - rh: 4
Outer skid shoe - lh: 4
Inner skid shoe - rh: 4
Inner skid shoe - lh: 5
Grate sealing clip - rh: 5
Grate sealing clip - lh: 10
Instrument Spares
Dp transmitter: 2
I / p convertor: 1
Air filter regulator: 0
Valve diaphragm: one set
Seats for critical valves: 7 nos.
Bearing for screw feeder: 0
Electricals Spares
Indication lamp: 0
Control fuses: 0
Contactor moving + fixed contact: 0
Sfu: 0
Acb moving + fixed contact: 0
Bimetal relay: 0
Push button: 0
Ammeters: 0
Hrc fuses: 0
Semi conductor fuses: 0
Tube expanders: one set
Safety valve locking seats for boiler hydro test: 3
Safety valve gaging arrangement: 3
Acc Tech. Datas
Design data
Turbine exhaust steam flow rate: 71 tph
Guaranteed back pressure: 0.18 ata
Steam enthalpy / dryness fraction: 580 / 0.93 k cal / kg
Temp. at tg exhaust: 57.4 deg. c
Cond. temp.: 56.25 deg. c
Heat rejected: 37304000 k cal / kg
Overall heat transfer coeff [bare / fin]: 678.15 / 30.44 k cal / hr. m2 deg. c
Mtd: 7.9 deg. c
Design ambient temp.: 42 deg. c
Outlet temp. of air: 52.5 deg. c
Altitude: msl m
Initial temp. difference - itd: 15.4 deg. c
Sound pr. level at 1 m: < 85 dba db - a
Fouling factor [tube / air side]: 0.000 / 0.0002 hr m2 eg.c/k cal
Performance Guarantee
Tg exhaust back pr. @ design point: 0.18 ata
Total power consumption for fans @ motor shaft: 89.6 x 6 bkw
Sound pre. level at 1 m below fan: < 85 db - a
Condenser Data
Modules size - [l x w]: 10.938 x 10.8 m x m
No. of modules: 6 nos
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.