Air cleaner - dry type with rain shield and service indicator
Barring device - manual
Bearings - heavy duty, replaceable, precision type
Breather - closed system
Connecting rods - forged steel, rifle drilled
Cooling system - choice of mounted radiator with pusher fan, core guard and duct adaptor, heat exchanger with surge tank, or connection for remote radiator cooling
Cylinder heads - interchangeable valve-in-head type. Two hard faced intake and two hard faced inconel exhaust valves per cylinder. Hard intake and exhaust valve seat inserts
Cylinders - vhp3600 series, 9.375″ (238 mm) bore x 8.5″ (216 mm) stroke. Removable wet cylinder liners. Number of cylinders - six
Enginator base - engine, generator and radiator or heat exchanger are mounted and aligned on a welded steel, wide flange base, designed for solid mounting on an inertia block, with standard through base holes for lifting
Engine protection shutdown contacts - for high water temperature, low oil pressure, high intake manifold temperature (standard engine mounted thermocouple with one thermocouple relay shipped loose), and overspeed (electronic speed switch - shipped loose). Also includes engine detonation sensing, alarm and shutdown, as standard. (See separate description of detonation sensing module.) One on/off pushbutton is supplied. Use all of the above in conjunction with a dc control panel for unit shutdown, (reference wps engomatic® controls)
Condition
Unit was bore scope and looks good
Kpc did the “top end end overhaul” including:
Full service / repair of heads
Radiator clean, flushed, and repaired
New set of spark plug, ignition coils and spark plug extension
New set of radiator belts
Service / repair of water pumps
New set of air /oil filter
Service of turbo charger – as needed
New gill ignition system
Load bank test, 100 % for one hour
Painted
Ready to go
Back end alternator was service, including:
Disassemble, steam clean and inspect generator
16 point bearing and housing inspection perform awa
Testing on stator, rotor, exciter rotor, exciter fields and re insulated
Check shaft run out measure and record shaft bearing fits
Dynamically balance rotor
Install new ball bearings
Lubricate and assemble generator
Included Accessories
Oil tank – grey
Silencer + exhaust flexible connection
Alternator
Leroy somers back end alternator, mtg 636, 105 temp rise, above 40 deg c
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.