Dresser Rand, 18 MW, 1989, Biomass Power Plant, 13,800 Volts, 60 Hz

Description

  1. Overview
    1. Biomass power plant with Dresser Rand steam turbine
    2. Capacity: 18.1 MW
    3. Year: 1989
  2. Steam Turbine Generator
    1. Dresser Rand 18 MW condensing steam turbine generator
    2. 3600 RPM
    3. 900 psig @ 790 F
    4. Woodward speed governor
    5. Electric Machinery generator
    6. 13,800 volts
    7. 3600 RPM
    8. 60 cycle
    9. 3-phase
  3. Lube Oil Cooler
    1. Dresser Rand twin lube oil cooler
    2. Shells: 2
    3. 202 sq. ft. per shell
    4. Shell 98 GPM of lube oil
    5. Tube 94.8 GPM of fresh water
    6. 250 psig @ 200 F, 150 psig @ 300 F
  4. Boiler System
    1. Zurn Energy boiler system
  5. Cooling Tower
    1. Thermal-Dynamic Towers cooling tower
  6. Condenser and Air Removal System
    1. Graham Mfg. Company condenser and air removal system
  7. Fabric Dust Filter
    1. Ultra Industries fabric dust filter
  8. Deaerator
    1. L.A. Water Treatment Company deaerator
  9. Feedwater Heaters
    1. Holtec International feedwater heaters
  10. Blowdown Tanks
    1. Penn Separator blowdown tanks
  11. Transformer
    1. General Electric 252 kVA transformer
  12. Additional Equipment
    1. Zurn air baghouse and scrubber
    2. Ransom Manufacturing ammonia storage tank
    3. Ash Tech mechanical ash handling system
    4. Burton Compressor Corporation compressors and dryers