Description Overview Turbomach (a Caterpillar company) gas turbine, type Taurus 70 (T 10301) Package assembly date: 2005 Package hours: 56,732 Turbine hours: 18,126 Gearbox hours: 31,553 Main Data (ISO No Losses) Electrical power: 7.52 MW Heat rate: 10,650 kJ/kWe-hr Fuel input: 22.25 MJ/s Efficiency: 33.8% Exhaust gas flow: 26.94 kg/s Exhaust gas temperature: 490 °C Fuel: NG Start system: DC Generator voltage: 6.3 kV Generator Unit (Leroy-Somer) Warning system: no brush Manufacturing standard: IEC 34 Unit 1 Nominal power (40 °C): 9,000 kVA Nominal output voltage: 6.3 kV Frequency: 50 Hz Efficiency at full load: 80% Power factor: 97.5% Speed: 1,500 cycle/min Steam Generation Type: not specified Flue gas flow: 23.36 kg/s Heating capacity: 6,720,000 kcal/h Steam capacity: 13.5 ton/h Maximum steam temperature: 173 °C Operating pressure: 8 bar Test pressure: 15 bar Boiler gas inlet temperature: 450 °C Boiler gas outlet temperature: 193 °C Gas Compressor (Enerproject) Flue gas flow: 25 kg/s Inlet pressure minimum: 13 bar Outlet pressure maximum: 24 bar