Description Overview Wartsila 41 MW single cycle power plant with 6 x 16V34SG gas generators Installed power: 41,820 kW at 31.5 kV, 50 Hz Fuel: natural gas Year of manufacturing: 2008 Operating hours: approximately 25,000 per unit Original heat rate (at alt. term): 8140 kJ/kWhe (44.2%) Plant own consumption: 836 kW Cooling system: closed loop radiators Status: in peak loading operation Engine Specifications Engines: 6 x W16V34SG, running at 750 rpm Engine design: four stroke, lean burn, pre chamber, spark ignited, port injected, trunk piston, turbocharged and intercooled Engines are designed for continuous operation in gas mode in island mode at any load between 40-100% of nominal power Alternator Specifications Alternators: 6 x AKV 8712 kVA, 11 kV, 50 Hz, p.f. 0.8 Control System Engine automation is a complete embedded management system, integrated with an engine control system for electricity controlled fuel injection Control system is a distributed bus based system where monitoring and control function is placed close to measuring and control point This leads to less wiring and improved performance Condition Very good operational condition Complete running power plant with 6 units of Wartsila 16V34SG spark ignited natural gas engine driven generators Equipment was delivered and commissioned by Wartsila in year 2008 and today the units have approximately 25,000 operating hours Engines need a 24,000 hour overhaul