Thermax Babcock & Wilcox, AFBC Steam Boiler, 2008, 110 TPH, 88 kg/cm2, 520 C

Description

  1. Specifications

    1. Main steam pressure at superheater outlet: 88 kg (194 lb)/cm2

    2. Main steam temperature at superheater outlet: 520 C (+/- 5 C)

    3. Fuel firing: Indian coal 100%, imported coal 100%, petcoke 100%

    4. Furnace: 11603 mm (456.8 in) long x 5908 mm (232.6 in) wide, heat surface area 1849 m2 (19,902.5 sq ft)

  2. Registration

    1. Current IBR registration certificate

  3. Condition

    1. Used, excellent condition

    2. On foundation, can be inspected