Siemens, SGT-300, 2007, Gas Turbine Cogeneration Plant, 7.9 MW, 50 Hz, 6.3 kV, Natural Gas, DLE (Same as V-3260)

Description

  1. Overview

    1. Used Siemens SGT-300 TEMPEST gas turbine cogeneration plant

    2. Includes Converteam generator and complete Heat Recovery Train

    3. Fuel: natural gas

    4. Dry Low Emissions (DLE)

    5. Year of manufacture: 2007

    6. Commissioned: 2008

    7. Operated until November 2025

  2. Performance

    1. Electrical output (ISO): 7.9 MW

    2. Site output (actual): approx. 7.6 MW

    3. Electrical efficiency: approx. 30.5%

    4. Exhaust gas temperature: 545 C (1,013 F)

    5. Exhaust gas mass flow: 30.2 kg/s (66.6 lb/s)

  3. Generator

    1. Converteam AC generator

    2. Rating: 9,800 kVA

    3. Voltage: 6.3 kV

    4. Frequency: 50 Hz

    5. Speed: 1,500 rpm

  4. Operating Data

    1. Operating hours: 116,131 h

    2. Number of starts: 677

  5. Control System

    1. Controller: Allen-Bradley ControlLogix

    2. Parallel with the grid and island mode

  6. Scope of Supply

    1. Gas turbine generator package

    2. Reduction gearbox

    3. Heat Recovery Train H210-H430

    4. Two exhaust stacks

    5. Spare parts

    6. Technical archive

  7. Heat Recovery Train

    1. H210 DOWTHERM A thermal oil: 4,300 kW (5,766 hp)

    2. H310 SANTOTHERM 66 thermal oil: 3,880 kW (5,203 hp)

    3. H410 high-pressure steam, 25 barg: 1,671 kW (2,241 hp)

    4. H420 low-pressure steam, 3.5 barg: 1,931 kW (2,590 hp)

    5. H430 hot water: 2,428 kW (3,256 hp)

  8. Service History

    1. 2020: generator overhaul

    2. 2021: grid-parallel and island-mode tests, up to 7 MW

    3. 2023: Type A service and borescope

    4. June 2025: replacement of the high-pressure bladed disc, seals and reconditioned SSS coupling, borescope

    5. September 2025: Type A service

    6. November 2025: end of operation