NovaStar, MS570, Acoustic Rock Wool Sandwich Panel, 50 mm (2 in), Perforated Inner Face (New)

Description

  1. Overview

    1. New insulated steel sandwich panel with a rock wool (mineral wool) core, 50 mm (2 in) thick.

    2. Acoustic version: the inner steel face is perforated, so the rock wool core absorbs sound inside the enclosure.

    3. Also available in 75 mm (3 in), 100 mm (3.9 in) and 150 mm (5.9 in) thickness, and as a solid (non-perforated) panel.

    4. For a generator enclosure, the 75 mm (3 in) perforated panel is recommended.

  2. Uses

    1. Acoustic enclosures, such as generator enclosures.

    2. Equipment rooms, studios and offices.

    3. Wall and ceiling cladding, roofs and interior partitions.

  3. Panel Size and Weight

    1. Thickness: 50 mm (2 in); 75 mm (3 in), 100 mm (3.9 in) and 150 mm (5.9 in) also available.

    2. Width: 1000 mm (39.4 in) standard panel width.

    3. Length: cut to the length the project needs.

    4. Weight of the 50 mm panel: 15.79 kg/m2 (3.23 lb/sq ft).

    5. Weight of the 75 mm panel: 18.59 kg/m2 (3.81 lb/sq ft).

  4. Core

    1. Hydrophobic (water-repellent) rock wool, Class A1 non-combustible.

    2. Density: 80 to 120 kg/m3 (5.0 to 7.5 lb/cu ft).

    3. Thermal conductivity: 0.041 W/m K (0.28 BTU in/hr sq ft F).

  5. Steel Skins

    1. Outer skin: 0.5 to 0.7 mm (0.020 to 0.028 in) G350 color-coated steel with a baked paint finish.

    2. Inner skin: 0.4 to 0.6 mm (0.016 to 0.024 in) G350 steel, perforated on the acoustic version.

    3. Color: white as shown; other coating colors to order.

  6. Performance

    1. Noise reduction: up to about 30 dB with the 75 mm (3 in) perforated panel, depending on how the enclosure is designed and installed.

    2. Heat transfer coefficient (U value) of the 50 mm panel: 0.839 W/m2K (0.148 BTU/hr sq ft F).

    3. Heat transfer coefficient (U value) of the 75 mm panel: 0.584 W/m2K (0.103 BTU/hr sq ft F).

    4. Fire: Class A1 non-combustible rock wool core.

  7. Joint and Fixing

    1. Tongue and groove interlocking joint.

    2. Concealed (hidden) screw fixing to the purlins or girts with self-drilling screws.

  8. Support Spacing (Double Span)

    1. 50 mm panel, by design load: 2,900 mm (9 ft 6 in) at 1.0 kN/m2 (20.9 psf); 2,200 mm (7 ft 3 in) at 1.5 kN/m2 (31.3 psf); 1,750 mm (5 ft 9 in) at 2.0 kN/m2 (41.8 psf); 1,450 mm (4 ft 9 in) at 2.5 kN/m2 (52.2 psf); 1,250 mm (4 ft 1 in) at 3.0 kN/m2 (62.7 psf).

    2. 75 mm panel, by design load: 4,000 mm (13 ft 1 in) at 1.0 kN/m2 (20.9 psf); 3,100 mm (10 ft 2 in) at 1.5 kN/m2 (31.3 psf); 2,550 mm (8 ft 4 in) at 2.0 kN/m2 (41.8 psf); 2,150 mm (7 ft 1 in) at 2.5 kN/m2 (52.2 psf); 1,800 mm (5 ft 11 in) at 3.0 kN/m2 (62.7 psf).

  9. Quantity

    1. 120 m2 (1,292 sq ft) of wall and roof panel.