Description OverviewScope of supply: GG and PT only; no generator, no enclosure, no controlsDuty since 2006: land-based power generation, natural gasSpecificationsOutput: 20 MWFrequency: 50/60 Hz (no alternator)Gas generator (GG): overhauled in 2006 and performance tested after the overhaulPower turbine (PT): new in 2006Hours since 2006: about 28,500Starts: about 430 in totalConditionUsed, overhaul requiredHot section is past its 25,000-hour intervalLast operated in 2012, installed in its enclosure sinceLast load test (2010): 17.4 MW at 23 °C (73°F), T5.4 at 750 °C (1,382°F), GG vibration under 1 milLast borescope (2010): compressor, HPT and PT with no findingsCombustor with partial coating burn, no material lossAll magnetic plugs cleanDocumentationBSI report availableInspection and load test records availableOperating hours by year available