New Laboratory Tenter Frame with Padder, 250 to 550 mm (9.8 to 21.7 in) Fabric Width, 235°C (455°F), 30 kW Electric Heating

Description

New as presented to American Plant and Equipment by the seller.

  1. Overview

    1. New laboratory tenter frame with padder: unwinding, padding, pinning, drying and winding in one continuous range

    2. Fabric width 250 to 550 mm (9.8 to 21.7 in)

    3. Fabric speed 0.2 to 5 m/min (0.7 to 16.4 ft/min)

    4. Maximum temperature 235°C (455°F)

    5. Electric heating 30 kW, 3 phase supply (minimum 3 x 200 V), built to the plant voltage

    6. Compressed air up to 7 bar (100 psi) and a water supply needed

    7. Approximate weight 1,000 kg (2,205 lb)

  2. Unwinding And Infeed

    1. Unwinding device

    2. Holding device for the batching roller including follower and clutch

    3. Pneumatic disc brake, maximum batch diameter 400 mm (15.7 in)

    4. Entrance and spreading device

    5. Spreading roller infinitely driven 0 to 400 rpm

    6. Two pneumatically controlled squeezing rollers, rubber covered, for selvedge control

    7. Width adjustment with spindle and hand wheel

    8. Device can be opened for cleaning

  3. Squeezing Device (Dyeing And Finishing Padder)

    1. Roller width 650 mm (25.6 in)

    2. Roller diameter 110 mm (4.3 in)

    3. Roller hardness 70° Shore

    4. Pneumatic load adjustment for maximum line pressure 230 N/cm

    5. Liquor trough, content 3.5 liters (0.9 gal), with dipping bow and guiding roller, trough without heating

    6. Outlet valve for trough

    7. Roller for the fabric guiding as well as finger safety guards

  4. Fabric Guiding And Overfeed

    1. Overfeed controller, range up to 40%, post-feed setting also possible, depending on the material

    2. Optical sensing device

    3. Two opto electronic edge feelers for the automatic positioning of the pinning-up device

    4. Two fabric guide elements, can be opened, with spreading action

    5. Two height adjusting devices

  5. Pinning-Up Device

    1. Pinning-up device with brushes

    2. Four pre-pinning brushes

    3. Two post-pinning brushes

    4. Can be opened, with locker

    5. Two pressing down bows, adjustable

    6. Two under feed rolls, rubber covered, as counter rolls, driven

  6. Chain And Width Adjustment

    1. Adjusting device for guiding rails

    2. Two guiding rails with pin chains

    3. Width adjustment by 2 servo motors, automatic optical sensor, push buttons for manual operation

    4. Maximum angle of chain ± 60 mm (2.4 in) at the entrance

    5. Digital indication of fabric width at the entrance

    6. Mechanical width adjustment of the chain by hand wheel at dryer entry and exit, with width indication

    7. Chain wheels, chain tensioners and length compensation

  7. Dryer

    1. Outer box with door, inner box with insulation between the two walls

    2. Removable cover (insulated)

    3. Two exhaust channels with adjusting flaps

    4. Circulation fan, infinitely variable; maximum capacity about 4,000 m3/h (141,000 cu ft/h)

    5. Nozzle box with air flap to adjust air flow top/bottom

    6. Fresh air fan, step switch

    7. Heating 30 kW, over temperature guard

    8. Covers at the dryer entrance and outlet

    9. Two devices for removal of the fabric from the pins with brushes

    10. Two safety switches

  8. Control And Instrumentation

    1. Control panel with operating elements and indicating instruments

    2. Electronic control for the 2.2 kW (3 hp) fan motor; air speed adjustable about 6 to 12 m/s (20 to 39 ft/s)

    3. Fan rotation control relay with air speed indicator

    4. Temperature measuring and regulating unit

    5. Heating control in 3 steps, added automatically on request

    6. Digital display of the fabric width at the spreading device

    7. Gear motor, infinitely variable with +/- percentage speed adjustment for the padder

    8. Gear motor, infinitely variable, for the pin chain and the upwinding device

    9. Motor boxes at entrance and exit, with all motor controllers

  9. Upwinding

    1. Upwinding device

    2. Holding device for the batching roller including follower and clutch

    3. Pneumatic adjustable control of the winding tension, maximum batch diameter 400 mm (15.7 in)

  10. Options Available

    1. Exhaust fan

    2. Second drying chamber, 30 kW, with its own circulation fan, fresh air fan and exhaust fan

    3. IR radiation pyrometer for contactless measuring of the sample surface temperature, with integrated cooling, at the dryer outlet

    4. Coating head for knife over roll, air knife and rubber blanket knife coating, maximum coating width about 350 mm (13.8 in), placed before the padder

    5. Liquor reservoir for a fixed coating width of 350 mm (13.8 in)

    6. Second doctor knife for high viscous pastes

    7. UL certification