Description Overview Five sets of 100 mw gas turbine generator sets Frequency: 60 hz Fuel: lng Built in: 1995 Stopped operation: middle of 2013 Gas Turbine Specifications Manufacturer: Westinghouse Model name: W501D5 Type: axial flow Power output: 100,000 kw (100 mw) Stages: 4 stage Inlet temperature: 1093 °c Exhaust temperature: 530 °c Exhaust flow: 1,313,272 kg/h Tac temperature: 15 °c Speed governor: dehc Starter System Type: electric motor Capacity: 1530 kw Quantity: 1 ea Combustor Type: can-annular Quantity: 14 ea Compressor Type: axial flow Air mass flow: 358 n㎥/min Inlet temperature: 15 °c Pressure ratio: 14:01 Outlet pressure: 14.462 kg/㎠ Stages: 19 stage Outlet temperature: 389 °c Generator Specifications (Gas Turbine) Manufacturer: Westinghouse (Siemens) Type: oac (open-air-cooled) Rated power: 129 (143) mw (mva) Power factor / short-circuit ratio: 90% / 0.695 Frequency: 60 hz / 2 pole Speed: 3600 rpm Rated voltage / current: 13.8 kv / 5731 a Insulation class: f Exciter (Gas Turbine Generator) Speed: 3600 rpm Exciter type: pmg Rated voltage / current: 325 v / 1006 a Protection devices: 87g, 59gn, 40, 32, 46, 51v, 60, 25 Neutral grounding: ngr Bus bar: ipb (3 phases) Rotation direction: cw (viewed from exciter end) Supply List Gas turbine Generator Control panel (electric package) Breaker Mechanical room equipment L/c t.r Steam turbine and generator Steam Turbine Specifications Manufacturer: Hitachi (Japan) Year: 1971 Overhaul year: 1997 Type: tcdf reheat condensing 23 Power output: 150,000 kw Rotor speed: 3,600 rpm Number of stages: hp 6 / ip 7 / lp 5 Main steam pressure: 100.1 kg/ Main steam inlet temperature: 498.2 Reheat steam inlet pressure: 34.4 kg/ Reheat steam inlet temperature: 353.9 Reheat steam outlet pressure: 31.7 kg/ Reheat steam outlet temperature: 501.5 Exhaust pressure: 38 mmhg (a) Speed governor: electro-hydraulic governor Generator Specifications (Steam Turbine) Manufacturer: Hitachi (Japan) Year: 1971 Type: tflh Rated power: 150 mw (mva) Power factor: 85% / 0.58 Frequency: 60 hz / 2 pole Speed: 3600 rpm Rated voltage / current: 17 kv / 6,521 a Insulation class: b Exciter (Steam Turbine Generator) Speed: 3600 rpm Exciter type: rotary rectifier Rated voltage / current: 284 v / 1,060 a Protection devices: 87g, 64g, 59f, 40f, 46f, 32, 21g Neutral grounding: grounding transformer Bus bar: ipb (3 phase) Super Heater Max. operating pressure: 121 kg/44? Outlet pressure: 91.9 kg/29.5? Outlet temperature: 484.4 ? /303 ? Re-Heater Max. operating pressure: 44 kg/? Max. operating temperature: 523.9 ? Outlet pressure: 29.5 kg/? Re-heat steam flow: 137.7 ton/h