Siemens, SGT-100-1S, 2004, 5070kW, 60Hz, Gas-Turbine Power Plant

Description

  1. Gas Turbine
    1. Maker: Siemens Typhoon
    2. Model: SGT-100-1S
    3. Year: 2004
    4. Rated output: 4,660 kW
    5. Maximum output: 5,070 kW
    6. Speed: 17,384 rpm / 1,800 rpm
    7. Fuel: Gas
    8. Low heating value: 40.6 MJ/Nm³
    9. Fuel consumption: 1,428 Nm³/h
    10. Exhaust gas flow rate: 54,800 Nm³/h
    11. Exhaust gas temperature: 542 °C
    12. NOx reduction measures: Premixed combustion (DLE)
    13. NOx emission value (GT outlet): 21 ppm under (0.2 = 16%)
  2. Generator
    1. Maker: Fuji Electric
    2. Model: GFV763ZB-4
    3. Year: 2003
    4. Rated output: 5,633 kVA - 5,070 kW
    5. Poles: 4
    6. Speed: 1,800 rpm
    7. Voltage: 3,300 V
    8. Frequency: 60 Hz
    9. Current: 986 A
  3. Gear
    1. Maker: Allen Gear
    2. Model: 21095-12
    3. Type: Star epicyclic gear
    4. Year: 2003
    5. Rated power: 6,266 kW
    6. Input speed: 17,370 rpm
    7. Output speed: 1,800 rpm
  4. Steam Turbine
    1. Output: 8,250 kW
    2. Pressure: 9.7 MPa
    3. Temperature: 510 °C
    4. Exhaust pressure: 0.49 MPa
    5. Speed (steam turbine): 9,100 rpm
    6. Speed (generator): 1,800 rpm
  5. HRSG Boiler
    1. Type: N-700P
    2. Maximum pressure: 11.4 MPa
    3. Normal pressure: 9.99 MPa
    4. Steam temperature: 513 °C
    5. Maximum steam quantity: 55 t/h
    6. Main steam pressure: 9.99 MPa
    7. Fuel: Gas
  6. Included
    1. All auxiliaries are included