Lubrication oil temperature engine inlet normal: °C 65
Lubrication oil temperature engine inlet derating 15%/30%, temp high: °C 67/69
Lubrication oil temperature engine inlet normal stop/shutdown: °C 71/73
Specific lubrication oil consumption: g/kWh 0.4
Lubrication oil consumption: kg/h 1.5
Crankcase lubrication oil volume high level: l 3320
Crankcase lubrication oil volume low level: l 2650
Rocker arm system normal pressure: barg 0.5
Rocker arm system alarm, pressure low: barg 0.2-0.3
Cooling Water Data
Two-stage charge air cooler low temperature stage temperature at inlet, max: °C 42
Two-stage charge air cooler low temperature stage water flowrate, normal: m3/h 100
Two-stage charge air cooler low temperature stage water flowrate, max: m3/h 150
Two-stage charge air cooler high temperature stage water flowrate, normal: m3/h 117
Jacket water system pump capacity: m3/h 117
Jacket water system normal stop/shutdown: barg 2
Jacket water system water quantity, engine block: l 620
Jacket water system temperature at engine outlet normal: °C 90
Jacket water system temperature at engine outlet alarm, temp high: °C 95
Jacket water system temperature at engine outlet shut-down, temp high: °C 97
Jacket water system temperature rise in engine, max: °C 4.6
Jacket water system temperature rise in engine including high temp CA-cooler: °C 7.1
Expansion tank volume, single-engined: l 300
Expansion tank volume, multi-engined: l 500
Expansion tank height above engine: m 3-10
Air Data
Turbocharger type: ABB TPS-57D_VTG
Charge air cooler type: UB29/36
Air consumption: m3n/h 16900
Air consumption: kg/h 21900
Charge air pressure: barg 1.7
Charge air temperature normal: °C 55
Charge air temperature derating 15%/30%, temp high: °C 58/60
Charge air temperature normal stop/shutdown: °C 62/64
Air pressure in engine room, min: mmWG 5
Exhaust Data
Mass flow: kg/h 22500
Volume flow, after turbine: m3/h 46300
Temperature, after cylinder: °C 495
Temperature, after turbine: °C 445
Back pressure, max: mmWG 400
Emission at MCR NOx - emission at 5% O2: mg/m3n 250
Emission at MCR CO - emission at 5% O2: mg/m3n 900
Emission at MCR NMHC - emission at 5% O2: mg/m3n 250
Heat Dissipation
Lubrication oil cooler: MJ/h 1860
Cooling water low temperature stage: MJ/h 895
Cooling water high temperature stage: MJ/h 1225
Jacket water cooler heat dissipation, engine: MJ/h 2240
Jacket water cooler heat dissipation including high temp CA-cooler: MJ/h 3465
Ventilation Data
Radiation engine: MJ/h 945
Radiation generator (IP23): MJ/h 540
Reference Conditions and Notes
Engine power definition is according to ISO 3046-1 and ISO 8528-1. However the engine ratings are valid for the following reference conditions: air inlet temperature max. +38°C, air inlet temperature min. +5°C, heat dissipation +25°C, charge air low temp cooling water inlet temp max. +42°C, site altitude above sea level max. 258 m, relative humidity 60%.
Charge air cooler heat dissipation will vary with water flowrate and inlet temp, these data to be calculated after receipt of final process data.
Specific energy consumption is according to ISO 3046-1 and is given at full load (MCR), running on natural gas with a lower heating value of 36.0 MJ/m3n and two engine-driven pumps.
Methane number min 70, according to AVL calculation.
Specific lubrication oil consumption is for guidance only.
Request a Quote
✓
Request sent
Thank you, our team will reply to you shortly.
Direct access to our team
Email American Plant & Equipment
Tell us what you want to buy, source, finance, or sell. A machinery specialist will follow up with you.
✓
Thank you. Your request is with the American Plant and Equipment team.
A machinery specialist will follow up with you.
Machinery updates
Subscribe to our email list
Tell us which industries you follow and we will send you the machines that match.
✓
You are on the list.
We will email you when machines that match your interests come in. Unsubscribe from any message.