NovaStar, MD136, Non-Invasive Ventilator, 3.5-inch LED Screen, CPAP/S/S/T/T Modes, 4-30cmH2O Pressure Range (New)

Description

  1. Overview
    1. Non-invasive ventilator
    2. Medical ventilator
    3. Certificate: CE
    4. Ventilator type: Electric control
    5. Scope of application: Treatment and titration of sleep apnea hypopnea syndrome, severe snoring, and respiratory insufficiency
  2. Ventilation Modes
    1. Ventilation mode: CPAP, S, S/T, T
  3. Pressure Specifications
    1. Pressure range: 4-30 cmH2O (±0.5 cmH2O)
    2. Pressure accuracy: +0.5 cmH2O
    3. Inspiratory phase pressure: 4-30 cmH2O
    4. Expiratory pressure: 4-30 cmH2O
    5. Expiratory decompression: Patient, off, 1-3, three adjustable
    6. Manual voltage regulation: 0-2 gear, 0-2 cmH2O (only available in CPAP mode)
  4. Parameter Settings
    1. Delayed boost: 0-60 min, set the division interval 5 min
    2. Initial pressure: 4 cmH2O treatment pressure / respiratory pressure setting
    3. Therapeutic pressure: 4-20 cmH2O (in CPAP mode)
    4. Target tidal volume: 150 ml - 1500 ml, on/off
    5. Maximum suction pressure: 4-30 cmH2O (can be set when the target tidal volume function is on)
    6. Minimum suction pressure: 4-30 cmH2O (not higher than the suction pressure), (can be set when the target tidal volume function is on)
    7. Inspiratory sensitivity: 1-8 stalls
    8. Expiratory sensitivity: 1-8 stalls
    9. Respiratory frequency: 3-40 times/min
    10. Inspiratory time: 0.3-3.0 s
    11. Backup rate: On/off, default 10
    12. Pressure rise time: 1-4 stalls
    13. Humidifier: 1-5 adjustable in 5 gears
  5. Titration Function
    1. Support manual and automatic pressure titration, built-in remote wireless communication module, complete the random switching of single and double level modes in the titration process, and control more than 11 ventilator parameters at the same time
  6. Auxiliary Functions
    1. Automatic air leakage compensation, automatic startup, automatic shutdown, delayed shutdown, screen backlight adjustment
  7. Monitoring Parameters
    1. Pressure, tidal volume, respiratory rate, minute ventilation volume, air leakage volume, inspiratory time, blood oxygen saturation
  8. Waveform Display
    1. Pressure time waveform, flow rate time waveform
  9. Alarm Prompts
    1. Pipeline and mask falling off, air leakage prompt, power interruption, treatment machine failure, humidifier failure, low voltage, high respiratory rate, low respiratory rate, low minute ventilation volume, low blood oxygen, replacement of filter cotton, full SD card, re insertion of SD card
  10. Data Management
    1. Network data: BMC + respiratory health management cloud platform
    2. SD card data: Resart NPAP data analysis software
  11. Included Parts
    1. SD card: Standard
    2. SD card slot: Standard
    3. Piping: 9 22 mm, 1.8 m long
    4. Face shield: F2 nose mask as standard
  12. Noise Level
    1. Noise: Less than 30 dB
  13. Environmental Conditions
    1. Temperature (when used): 5-35 °C
    2. Temperature (during transportation and storage): -20 °C to 55 °C
    3. Atmospheric pressure (when used): 760-1060 hPa
    4. Atmospheric pressure (during transportation and storage): 760-1060 hPa
    5. Working hours: More than 8 hours
  14. Power Supply Requirements
    1. AC voltage: 100-240 V
    2. Frequency: 50 Hz/60 Hz
    3. Input power: Less than 2 A
    4. Waterproof level: IP22 - drip proof equipment
  15. Dimensions and Weight
    1. Instrument size: 290 mm x 180 mm x 134 mm
    2. Weight: 1.5 kg (excluding humidifier), 2.5 kg (including humidifier)