Description Overview Tedom model micro T35AP - LPG gas Year 2018 Gas-powered micro cogeneration unit Also known as a combined heat and power (CHP) unit Designed to generate heat and electricity from LPG (liquified petroleum gas) Specifications 35-kW nominal electrical output 242,260 BTU (71 kW) maximum heat output 378,750 BTU (111 kW) fuel input 31.5% electrical efficiency 64% heat efficiency 95% total efficiency (fuel utilization) 302 CFH (6.6 kg/h) gas consumption at 100% power Emissions at 15% O2 in exhaust gases: CO - 2 g/bhp-hr NOx - 1 g/bhp-hr, VOC - 0.7 g/bhp-hr Complete with 4-cylinder inline engine, 231 cui displacement 1800 rpm, 120 x 120 mm bore/stroke 44-kVA generator at 93.2% efficiency 60 Hz electrics Thermal System 242,260 BTU (71 kW) total system heat recovery 13.3 gpm (0.85 kg/s) nominal flow rate 87 psi (600 kPa) maximum working pressure 158°F (70 °C) maximum return water temperature 104°F (40 °C) minimum admissible return water temperature Combustion Air and Exhaust 60.6 CFM (82.7 m³/hr) amount of combustion air 50 to 95 °F (from 10 to 35 °C) required combustion air temperature 248/302 °F (120/150 °C) exhaust gas temperature, nominal / max 0.15 psi (10 mbar) maximum back-pressure of exhaust gases downstream of flange 66.5 CFM (128 m³/hr) amount of exhaust gases Included Components Complete with (2019) Yazaki model WFC-SC10 (1) WFC-SC20 – each cogen will come with a chiller 120,000 BTU cooling 171,400 BTU/hr heat input 291,400 heat rejection Tedom type micro R – Intelipro interconnection switchboard II control panel Armstrong model 1.5 x 1.5 x 8 4380 commercial pump Armstrong model DE 4380 026-005-0055 design envelope pumping unit CTS model T225 cooling tower 7,000 CFM Condition Never used / installed