MAN, MARC 4B, 2007, 16MW, 50Hz, Back Pressure Steam Turbine Generator

Description

  1. Overview
    1. Back pressure steam turbine generator
    2. 16 MW
    3. 50 Hz
    4. 10,500 V +/-5%
    5. Turbine year 2007, alternator year 2008
    6. Shut down December 2017
  2. Turbine
    1. Engine: Man Marc 4B 2008
    2. 16,230 kW, 8,120 RPM
    3. Fresh steam: 99 bar
    4. Steam consumption: 129.2 ton/hour
    5. Finished steam pressure: 7 bar
    6. Fresh steam temperature: 410 deg C
    7. Used steam temperature: 165 deg C
  3. Generator
    1. Manufacturer: Jeumont Electric 2008
    2. 16,240 kW, 20,300 kVA, 10,500 V +/-5%
    3. 1,116 A, 50 Hz, 1,500 RPM, 0.8 power factor
    4. Total hours: 60,145 hours, shut down on 2017
    5. After last overhaul on 2010 till shut down: 9,399 hours
  4. Gearbox / Transmission
    1. Manufacturer: Renk AG 2007
    2. Nominal power: 17,050 kW
    3. Configured power: 18,650 kW
    4. 8,120 / 1,500 RPM
  5. Support Systems
    1. Lubrication system: Reinhold Wesselmann GmbH 2007
    2. Control oil system: Hydrac System GmbH 2007
    3. Fire extinguishing system: Van Winkel en Boerma 2008
  6. Included
    1. Central control and operating cabinet
  7. Condition
    1. This lot still available