Description Overview Condition: Used Year: 2008 Back-pressure turbine 22.5 MW 26 MVA In operation since 2009 Running time: 24,000 h Operation manual in English Turbine Specifications Siemens SST 300 G32 A extraction back-pressure turbine Revolution: 8274 rpm Inlet pressure: 90 bar a Inlet temperature: 525 °C Inlet flow (min/max): 7.93/33.5 kg/s Tap-off pressure (min/max): 3.7/24.1 bar a Tap-off temperature (min/max): 259-357 °C Tap-off flow (min/max): 7.9/33.5 kg/s Outlet pressure: 3.4 bar a Outlet temperature (min/max): 144/205 °C Outlet flow (min/max): 7.9/33.5 kg/s Generator Specifications Brand: Siemens Teho Generation AG, Germany Type: SGEN5-100A-4P Nominal output: 28.5 MVA Reactive power: 22.8 MW Voltage: 6.3 kV (+5/-10 %) Rated current: 2612 A Frequency: 50 Hz In operation 2009 to 2012 Operation hours: 24,000 Included Equipment Turbine Gearbox Turning gear Generator Generator cooler Oil system Siemens automation system Automation and electrical equipment (as it is on the field) Motors Frequency changers Valves Auxiliary devices (as it is on the field) All available existing specific spare parts