Description Overview Wartsila power plant Commercial operation start: January 2010 Contract status: Operated under standby mode until December 2024 20 x Wartsila 20V32 8.45 MW each, 60 Hz HFO, but convertible to diesel or biodiesel. Green. Specifications 20 generating sets (gensets) mounted on steel spring foundations Synchronous three-phase generators with turbocharged diesel engines Comprehensive auxiliary systems: fuel treatment and booster systems Black start generator Charge air, cooling water, and exhaust systems Steam generation and compressed air systems PLC-based control and monitoring with central and local panels MV power distribution with generator cubicles, switchgear, and transformers Capacity: 169 MW (20 x 8.45MW each) Current Condition Running hours: Most gensets remain within optimal maintenance ranges 70% of units are below or approaching 6,000 hours, well below overhaul threshold Clean and well-maintained mechanical and electrical infrastructure Dismantling-ready: All systems modular and feasible for relocation Scope of Supply Civil works: Buildings and civil structures that can be dismantled Mechanical equipment: All equipment and auxiliary units/modules Electrical and control: Panels, cabling, etc. (excluding high-voltage system) Key Systems Description Genset: Diesel engine + synchronous generator on a flexible base Engine modules: Lubrication, fuel, cooling, and exhaust modules steam tracing, separators, silencers, etc. Black start unit: Independent generator for startup without grid support Fuel treatment: Separator units with pumps and heaters Compressed air system: For engine start and pneumatic operations Cooling system: Low-temperature and high-temperature water circuits Charge air system: Turbocharged and intercooled intake air Exhaust system: Heat recovery + noise reduction Steam generation: Exhaust heat + auxiliary boiler Control system: Central + local panels, PLCs, synchronizers Power distribution: MV switchgear, transformers, protection relays (HV not included) Packing list: Engines, generators, modules, auxiliary systems, etc. Additional notes: High voltage system not included in scope Condition and modularity: System is designed for modular disassembly and transport Very good condition Option to buy plant along with land