150 MW gas turbine generator co-generation power plant
Westinghouse CW251B12A turbines
46,690 kW rating at 5,427 rpm under site conditions
Site conditions: 45 degrees Fahrenheit, 4.6 in H2O inlet pressure, 19 in H2O, 105 degrees Fahrenheit max turbine inlet, 1050 degrees Fahrenheit, 383 lb/s air flow
Fuel: natural gas / no. 2 distillate
Unit Histories
CT1: ebh since last outage 7,367, e starts since last outage 161, lifetime ebh (hours) 88,679, hours since last major 36,331, hours since last hgp 16,753
CT2: ebh since last outage 5,338, e starts since last outage 57, lifetime ebh (hours) 89,861, hours since last major 40,216, hours since last hgp 15,147
CT3: ebh since last outage 9,301, e starts since last outage 489, lifetime ebh (hours) 74,960, hours since last major 26,777, hours since last hgp n/a