Hurst, Series 45, 2016, 207.5 HP, 60 PSI Hot Water, Natural Gas Boiler

Description

  1. Overview
    1. Machine type: Boiler, natural gas
    2. Year of manufacture: 2016
    3. Condition: New, never used
    4. Never installed and ready for delivery
    5. Actual model: Hurst S45-G-207.5-60W
  2. Specifications
    1. 207.5 hp
    2. 60 psi hot water
    3. Natural gas fired firebox
    4. Efficient 3-pass design natural gas firebox
    5. Asme code constructed and stamped for 15 psi steam; 30-100 psi water
    6. Registered with the National Board of Boiler Inspectors
    7. Electric voltage: 480 V, 60 cy, 3 ph
    8. Hot water pressures models are from: 8.5-415 hp; 100 psi max.; 500-813 hp; 60 psi max. Built to section-IV ASME code
    9. Hot water temperature not to exceed 250 degrees F at or near the outlet of boiler
    10. Hot water supply: 180 dif return: 160 dif
    11. Fireside heating surface: 830 sq/ft
    12. Furnace volume: 132 cu/ft
    13. Hot water outlet: 8; hot water drain: 6; drain connection: 2 in
  3. Design And Construction
    1. Boiler design: 3-pass "firebox" design with stress relieving "wetback" fire tube construction
    2. Wet back construction
    3. Unified refractory base floor; steel skids; lifting eyes
    4. Low heat release; factory insulated with 2 in mineral wool, factory jacketed and painted
    5. High density 2 in mineral wool insulation assures lower radiant heat loss
    6. Easy access to fireside surfaces; ample waterside clean-out openings
    7. Easily maintained, designed for efficiency; large furnace volume for ultimate combustion efficiency
  4. Controls And Burner
    1. Fully automatic operation; U.L. listed; forced draft burners
    2. U.L. listed controls and trim
    3. Burner: matched UL listed "forced draft" power burners with factory pre-piped, wired and tested fuel configurations for natural gas, propane (LP) gas, No. 2 (diesel) oil, or combination of both gas/oil
    4. In addition to meeting the requirements of U.L., burner systems are optionally available to meet the requirements of FM, IRI, military, and others
    5. Hot water model trim: safety relief valve; operating temperature control; high limit temperature control with manual reset; combination pressure and temperature gauge; low water cutoff control with manual reset
  5. Included And Testing
    1. All units are factory packaged with operating controls, relief valves, burner, and fuel train. Installation is made simple in that only service connections are needed to place in operation
    2. Factory test fired, flame observation ports front and rear