Description Overview Standards: 16 CFR 1610, ASTM D1230, CA TB117, GB/T 14644, JIS L1091 Test chamber: 370 mm x 220 mm x 350 mm, top 12 vents with diameter of 12.7 mm Sample frame: 45° Sample clip: upper plate grooved 38 mm x 152 mm Distance between nozzle axis and rotation axis: 44 mm Distance between nozzle and sample surface: 8 mm Flame nozzle distance marker: 127 mm Brush weight: 150 gf Sample size: 50 mm x 150 mm Specifications Volume (w x d x h): 420 x 260 x 520 mm Weight: 20 kg (a) and 10 kg (b) Power supply: 1 ac 220 v, 50 hz, 3 a Sample frame angle: 45 degrees Included Accessories Marked cotton thread: mercerized cotton sewing thread Test fixture: 5 sets igniter Auxiliary tools: 50° dry cleaners (available separately) Gas supply device oven (additional)