MAN B&W, 6L23/30H & 7L23/30H, 1999-2000, 962 kVA & 1125 kVA, HFO Fired Generator Sets

Description

  1. Overview
    1. Man B&W make HFO fired generator sets
    2. 962 KVA and 1125 KVA
    3. 50 Hz
    4. HFO fired generator sets
  2. Item 001
    1. 1125 KVA each, MAN B&W make
    2. Type: 7L23/30H
    3. HFO fired generator sets complete with all their auxiliaries and accessories
    4. Quantity: 6
  3. Item 002
    1. 962 KVA each, MAN B&W make
    2. Type: 6L23/30H
    3. HFO fired generator sets complete with all their auxiliaries and accessories
    4. Quantity: 10
  4. Engine Details
    1. Brand: MAN B&W diesel
    2. Year of make: 2000
    3. Engine type: 6L23/30H - 7L23/30H
    4. Power: 962 KVA - 1125 KVA
    5. Speed: 750 RPM
  5. Generator Details
    1. Brand: AVK synchronous generator
    2. Year of make: 2000
    3. Type: DSG86K1-8 - DSG86M1-8
    4. Capacity: 962 KVA - 1125 KVA
    5. Voltage: 415 V
    6. Frequency: 50 Hz
    7. P.F: 0.8
    8. Ins. class: H
    9. Coolant temperature: 45°C
    10. Speed: 750 RPM
    11. No. of phase: 3
    12. Excitation: 45 V
    13. Amp: 3.7
    14. Aux excitation: 82 V
    15. Current: AC
    16. Type of enclosure: IP 23
  6. Oil Separator Details
    1. Brand: Alfa Laval
    2. Separator type: MMPX 404 SGP-11, FOPX 605 TFD-24
    3. Year of make: 1999 to 2000
    4. Inlet & outlet: 561313-01, 546226-01
    5. Bowl: 561137-01, 546224-04
    6. Machine bottom part: 561371-01, 540224-10
    7. Maximum speed (bowl): 9510 R/M², 7605 R/M²
    8. Speed motor shaft: 3000 RPM, 1500 RPM
    9. El. current frequency: 50 Hz
    10. Motor power: 3 KW - 4 KW
    11. Maximum density of feed: 1100 KG/M³
    12. Maximum density of sediment: 2332 KG/M³, 1896 KG/M³
    13. Maximum density of operation liquid: 1000 KG/M³
    14. Process temperature min./max.: 0/100°C
  7. Condition and Operation
    1. All the generators have been operated for a total of around 38000 to 40000 hours.
    2. Major overhauling (due at 36,000 hours) has been completed for all the generator sets between 34500 to 36500 hours.
    3. The total operation after the last overhauling is around 3500 to 4500 hours only.
    4. The generators have been shut down completely in July 2025 and are in excellent condition.
    5. Running trials of the units have been done in mid-August 2025 and videos of the same can also be shared with you, if desired.
    6. Since 2 generators share common accessories, it would be preferred to sell the generator sets as pairs of 2 units.
    7. Alternator can be operated on higher speed of 900 RPM, 60 Hz or alternator can be replaced with another 60 Hz alternator.
    8. Machines in running condition. Trial run was last completed in mid August 2025.
    9. Fuel: HFO
    10. These are land generators.