GE, Frame 9FA, 2012, Combined Cycle Gas Turbine Power Plant, 750 MW, 50 Hz, Dual Fuel

Description

  1. Overview
    1. Based on GE Frame 9FA technology, supplied, installed, but not commissioned.
    2. The plant equipment is available as a complete package, including major equipment, auxiliaries and balance of plant (BOP).
  2. Plant Configuration Overview
    1. Total configuration:
    2. 2 × GE Frame 9FA gas turbines
    3. 2 × CMI triple pressure HRSG
    4. 1 × GE steam turbine
    5. Combined cycle output: ~750 MW per block
    6. Status: installed / partially installed
    7. Not commissioned
    8. Units have never been fired or operated
  3. Gas Turbine Island
    1. Gas turbines
    2. Quantity: 2 units
    3. Brand: GE
    4. Model: Frame 9FA +e DLN2+
    5. Fuel: dual fuel
    6. Frequency: 50 Hz
    7. Site rated output: 241,000 kW per unit
    8. Year of manufacture / delivery: 2012
    9. Status: installed, unused
    10. Gas turbine generators
    11. Brand: GE
    12. Rated capacity: 310,725 kVA
    13. Gas turbine transformers
    14. Brand: Hyundai
    15. Type: oil-filled
    16. Rating: 335 MVA
    17. Voltage: 15.75 kV
  4. Steam Turbine Island
    1. Steam turbine
    2. Quantity: 1 unit
    3. Brand: GE
    4. Model: GE-D11
    5. Type: condensing
    6. Rated output: 276,040 kW (370,175.7 hp)
    7. Configuration:
    8. HP: 10 stages
    9. IP: 8 stages
    10. LP: 2 × 5 stages
    11. Status: unused, packaged and stored
    12. Steam turbine generator
    13. Brand: GE
    14. Rated capacity: 324,760 kVA
    15. Steam turbine transformer
    16. Brand: Hyundai
    17. Type: oil-filled
    18. Rating: 335 MVA
    19. Voltage: 15.75 kV
  5. Heat Recovery Steam Generators (HRSG)
    1. Quantity: 2 units
    2. Brand: CMI – Belgium
    3. Type: triple pressure, horizontal, natural circulation
    4. Status: approx. 90% mechanically constructed
  6. Auxiliaries & Balance of Plant (BOP)
    1. A complete auxiliary and BOP scope supplied primarily by Aker Solutions, including:
    2. Black start system – Sterling Wilson
    3. Distributed control system (DCS)
    4. GE Mark VIe control system for GT & ST
    5. Cooling towers – Hamon
    6. Electrical BOP & switchyard equipment
    7. Hyundai power transformers
    8. Fuel gas conditioning system
    9. Pumps (CW, vertical, horizontal, ACW booster)
    10. Piping, valves, heaters, instrumentation
    11. Isolated phase bus duct
    12. HT switchgear, control & relay panels
    13. Unit auxiliary transformers
    14. Cabling, cable trays, grounding systems
  7. Installation & Storage Status
    1. Major equipment installed but not commissioned
    2. HRSG: partially erected (~90%)
    3. Steam turbine: stored, unused
    4. Approximately 400 containers of equipment remain stored and not yet installed, including: electrical systems
    5. Mechanical auxiliaries
    6. Piping & hardware
    7. Instruments & control components
    8. Shelf-life items (batteries, filters, paints, etc.)
  8. Warranty Status
    1. The plant has not been commissioned, therefore:
    2. Original GE warranty has not been consumed
    3. GE warranty reactivation is possible
    4. Subject to payment of an applicable fee, GE can reinstate and warrant the units
  9. Commercial Notes
    1. Available as complete package or by negotiated scope
    2. Ideal for fast-track deployment
    3. Significant savings compared to new-build lead times
    4. Immediate availability subject to agreement
    5. Quantity: 2