Elevator Structure FEA Stress Test Report

Description

  1. Overview
    1. Can make roofs up to 36 meters wide without support for the structure
    2. Thickness of steel coils depends on the width of the roof; from 0.8 mm for smaller roofs to 1.5 mm for the widest roof
  2. Condition
    1. The machine has only done one test run
    2. The spray-foam machine is unused and still in original packing
  3. Included
    1. Includes test coil of 1.5 ton
  4. Specifications
    1. Nodes: 89715
    2. Elements: 77727
    3. Max stress: 138 MPa
    4. Analysis type: Finite Element Analysis (FEA) Static Analysis