NovaStar, Profile Vu, Flaw Detection System, 2m Travel Linear Slide, Non-Contact Thickness Measurement (New)

Description

  1. Overview
    1. First unit of this style produced by NovaStar.
    2. Uses the same technology as the Profile Vu series of flaw detection equipment.
    3. System mounts two opposing gauges to measure thickness, instead of the three-gauge ring layout.
    4. Fixture must be over 2 m long if mounted on a linear slide to obtain measurements over the entire product width.
    5. If only measuring the edge of the product, the system can be significantly shorter.
  2. Linear Slide
    1. Linear slide holds the C frame and has 2 meters of travel.
    2. Slide includes a laser micrometer and monitor attached (as shown in picture).
    3. Monitor to view measurements is not mounted to the linear slide.
  3. Included Items
    1. Linear slide with 2 m travel.
    2. Laser micrometer.
    3. Monitor (not mounted to slide).
  4. Excluded Items
    1. Part holding or handling system.
    2. Product must be well controlled in the field of view by the buyer.
  5. Technology Capability
    1. Profile Vu flaw detection system technology is capable of measuring sheet and fabric thickness.
    2. Many PV flaw detection systems have been sold by the team.