Description OverviewSiemens SGT-600 heavy-duty industrial gas turbine, single-shaft core engine with a 2-stage free power turbineDry Low Emissions (DLE) combustion system, dual-fuel capable (natural gas or liquid fuel)Siemens Simatic S7 control systemTechnical Specifications (Siemens' published nominal data for the SGT-600 model)Power generation: 24.77 MW(e) (ISO)Frequency: 50/60 HzElectrical efficiency: 34.2%Heat rate: 10,533 kJ/kWh (9,983 Btu/kWh)Turbine speed: 7,700 rpmCompressor pressure ratio: 14:1Exhaust gas flow: 80.4 kg/s (177.3 lb/s)Exhaust temperature: 543°C (1,009°F)Axial compressor: 10-stage, 2 stages variable guide vanesCombustion: 18 dual-fuel 2nd-generation DLE burnersCompressor turbine: 2-stage axial-flow, both stages air-cooledPower turbine: 2-stage free power turbine, uncooledGenerator: four-pole, rated voltage 10.5/11.0/13.8 kV, protection IP54Overhaul interval: 40,000 hoursPackage length 18.7 m, width 4.1 m (driver) / 4.6 m (generator), height 7.8 m (engine), 11.9 m to top of packageNotesFigures above are the manufacturer's published nominal specifications for the SGT-600 model; year, running hours and condition available on request