Solar, Taurus 60, Gas Turbine, 5,670 kW

Description

  1. Overview
    1. Solar Taurus 60 (T60 / GT60) industrial gas turbine generator package, rated 5,670 kW (5.67 MW) at ISO conditions, 50 Hz.
    2. Single-shaft layout with a SoLoNOx dry low-emission combustion system and Turbotronic S4 control.
    3. One unit available, used, with 100 operating hours.
    4. Complete OEM drawings and factory test certificates are provided with the machine.
  2. Power and Efficiency
    1. Simple cycle net output: 5.67 MW.
    2. Simple cycle thermal efficiency: 31.5 percent, heat rate 11,430 kJ/kWh (10,834 Btu/kWh).
    3. Combined heat and power total energy utilization efficiency: 80 to 88 percent.
    4. Steam generation: 13.5 t/h (29,762 lb/h) of saturated steam unfired, up to 58.9 t/h (129,852 lb/h) with supplementary firing.
    5. Stable load range: 40 to 100 percent of rated power.
  3. Exhaust and Air Data
    1. Exhaust mass flow: 78,385 kg/h (172,810 lb/h).
    2. Exhaust temperature: 510 C (950 F), axial exhaust layout.
    3. Inlet air mass flow: 21.5 kg/s (47.4 lb/s).
  4. Mechanical Design
    1. Single-shaft layout with a 12-stage axial compressor and three variable inlet guide vanes.
    2. Compression ratio: 12.2:1.
    3. SoLoNOx dry low-NOx combustor, with NOx emission down to 9 ppm without water injection.
    4. Multi-stage air-cooled turbine.
    5. Turbotronic S4 integrated PLC control with remote monitoring; full load is reached within 4 minutes.
    6. Package dimensions (length x width x height): 9.8 x 4.0 x 2.5 m (32.2 x 13.1 x 8.2 ft).
    7. Total package weight: approximately 24.8 metric tons (27.3 short tons), with a standard acoustic enclosure rated 85 dBA.
    8. Matching generator: 6.3 kV or 10.5 kV synchronous generator on an integrated skid with a reduction gearbox.
  5. Fuel Compatibility
    1. Standard dual fuel: natural gas and light fuel oil, with seamless switching while running.
    2. Alternative fuels: biogas, landfill gas, coke oven gas, low-BTU industrial waste gas and hydrogen blends.
    3. Dry low emission design; no water treatment is required.
  6. Scope of Supply
    1. T60 gas turbine main unit and synchronous generator on an integrated base skid.
    2. Air intake filter and silencer, exhaust duct, and lube oil and cooling package.
    3. Turbotronic control cabinet and CO2 fire suppression.
    4. 6.3 kV or 10.5 kV grid switchgear and a heat recovery steam generator interface.
    5. Full OEM technical documents and test reports.
    6. On-site installation and long-term maintenance are excluded.
  7. Applications
    1. Industrial park combined heat and power, hospital and hotel distributed power, ceramic and paper mill self-generation, small oil and gas power stations, data center backup power, and landfill gas power plants.
    2. Compact skid design for outdoor installation without a building, with a short construction period.
  8. Condition
    1. Condition: used.
    2. Operating hours: 100.