Description Overview Natural gas fired thermal oil boiler Rated power: 2400 kW Outlet oil temperature: 300 °C Inlet oil temperature: 275.7 °C Circulation flow: 160 m³/h Working pressure: 0.8 MPa Fuel: natural gas Fuel consumption: 294.32 N m³ per hour Air temperature: 25 °C Thermal efficiency: 98.5% Oil volume in the furnace: 1.77 m³ Combustion System Burner, 1 set, Reillo Chimney, 15 meters, material: Q235-B Explosion door, 1 set, material: Q235-A Circulation System Boiler body, 1 pc High temperature circulation pump, 2 pcs, 45 kW Filling pump, 1 pc, 1.5 kW Y-type filter 1, 1 pc, cast steel Y-type filter 2, 1 pc, cast steel Oil/gas separator, 1 pc, material: Q235-B Expansion tank, 1 pc, material: Q235-B Oil storage tank, 1 pc, material: Q235-B Instrument Control System Electric control cabinet, 1 pc Bimetallic thermometer, 2 pcs, 0 to 400 °C Platinum resistance, 2 pcs, 0 to 400 °C Electro connecting pressure gauge, 2 pcs, 0 to 1.6 MPa Float ball level meter, 1 pc, expansion tank Glass plate level gauge, 1 set, expansion tank / oil storage tank Thermometer socket, 2 pcs Thermal resistance socket, 2 pcs Pressure gauge socket, 2 pcs Pressure gauge buffer tube, 2 pcs Pressure gauge needle valve, 2 pcs SpecificationsBurner brand: Riello