Description Overview Plant is typical cogeneration for process steam generation from HRSG only; no steam turbine running. Manufacturer: General Electric GE Frame size: PG9171 Gas turbine model: Frame 9E Gas turbine design output at 19 °C ambient temperature: 123,800 kW Fuel and Starting System Fuel system: gas only Starting: electrical motor Air and Exhaust System Air filtration: self cleaning Compressor washing: on and off-line compressor water wash Exhaust system: side left Emissions and Fire Protection Emissions control: gas-dry low NOx Fire protection: high pressure CO2 Generator Model: 9A5 Frequency: 50 Hz Power factor: 0.8 lagging (capability to 0.95 leading) Control Systems Gas turbine: Speedtronic Mark VIE (TMR) Generator: control, excitation, regulation and protection panel Operator interface: local and control room HRSG Manufacturer: Nooter/Eriksen Steam generation capacity: 212 t/h, 41 barg, 435 °C SpecificationsCapacity: 123,800 kW (123.8 MW)