NovaStar, EC167, Altitude Test Chamber, 2000 L, -70 to 150 deg C, 200,000 Feet Altitude Range
Scroll to zoom
100%
Description
Overview
Altitude test chamber is a 2000 L chamber configured to simultaneously test temperature and low-pressure altitude conditions.
Offers a wide range of temperatures with optional humidity testing suitable for assessing various mixed-environmental conditions.
Equipped with stimulation of high altitude conditions with a water cooled cooling system for user convenience.
Used in testing of avionics, electronic, automotive equipment, defense and aerospace applications where intense pressure and vacuum conditions are encountered.
Features
Altitude testing range - 200,000 feet
Balanced temperature and humidity control system
Sight window for visual observation of sample analysis
Interior light for enhanced visualization
Optional humidity control system
Water cooled cooling system (semi-hermetic compressor)
Robust vacuum system (reliable and flexible tests)
Cable access ports
Specifications
Chamber capacity: 2000 L
Interior dimensions (W x H x D): 1200 x 1200 x 140 mm
Exterior dimensions (W x H x D): 1650 x 2600 x 2450 mm
Temperature range: -70 °C to 150 °C
Constant temperature: ± 0.5 °C
Temperature deviation: ± 2.0 °C (constant pressure without loading)
Cooling rate: 0.7 °C to 1.0 °C / min
Pressure range (constant): ~ 0.5 kPa
Pressure deviation (≥ 40 kPa): ± 2 kPa
Pressure deviation (4 kPa to 40 kPa): ± 0.5 kPa
Pressure deviation (≤ 4 kPa): ± 0.1 kPa
Depressurization rate: ~ 1 kPa ≤ 30 min (constant pressure at RT)
Pressure recovery rate (adjustable): 10 kPa / min
Refrigeration system: water cooled, semi-hermetic compressor
Heater: iron-chrome wire heater
Temperature sensor: PT100
Controller screen panel: 7-inch LCD touch-screen
Vacuum method: rotary vane vacuum pump
Temperature regulating method (adjustable): balanced temperature / humidity system