NovaStar, FT117, Flammability Tester, Cabinet Capacity ≥0.5 m³, AC220V (New)

Description

  1. Overview
    1. Tests electrical product components of household appliances, spare parts and components, such as household appliance insulation shells, panel switches, printed circuit boards and insulation materials.
    2. Design standards: L94, GBT2408, IEC60695, GB470.
  2. Specifications
    1. Cabinet capacity: ≥0.5 cubic meters, with glass watch door.
    2. Ignite time: 0 to 99 minutes and 99 seconds can be set.
    3. After flame time: 0 to 99 minutes and 99 seconds can be set.
    4. Residual burn time: 0 to 99 minutes and 99 seconds can be set.
    5. Combustion angle: 20°, 45°, 90° (equal to 0°) can be adjusted.
    6. Burner size parameter: nozzle diameter ⌀9.5±0.3mm, nozzle effective length is 100±10mm, with air adjust hole.
    7. Power: AC220V±10% 50Hz.