Pneumatic level control used to detect adhesive level in reservoir and provide a signal to operate the fill pump and maintain a constant level in reservoir (+/- 1/8").
Control utilizes an aluminum tube inserted into the reservoir at the desired fill level of the adhesive.
Control detects the level pneumatically and incorporates a high level failsafe feature to ensure against overfilling of the reservoir.
Control also includes a timing relay to cancel out intermittent or false trigger signals and can be used to allow a greater drop in level until refilling occurs.
Output of the level controller can be configured to generate a voltage output to operate a solenoid, or a dry isolated contact output to interface to a pump control circuit.
Specifications
Electrical requirements: 120 VAC 2A.
Pneumatic requirements: 20 psi clean, dry air, less than 1 scfm.
Physical size (control box): 8" x 12" x 6".
Dimensions: 8x12x6 inches