Two Siemens SGT5-4000F/V94.3A gas turbines, manufactured by Siemens.
Each unit has a nominal net site rating of approximately 230 MW.
Dual-fuel type: natural gas or distillate.
Year of manufacture: 2001.
Specifications
Fuel: gas / liquid fuel.
Nominal continuous site rating: 230 MW.
Operating speed: 3000 rpm.
Number of compressor stages: 15.
Number of turbine stages: 4.
Compressor site pressure ratio: 18:1.
Gas turbine site exhaust temperature: 601 °C.
Type of combustion: annular.
Number of burners: 24.
Minimum natural gas pressure: 23.3 bar.
Liquid fuel type: distillate.
Starting system: SFC.
Operating Hours
Total equivalent operating hours (EOH) for each unit at TG2 since commercial operation, up to 27th February 2023: GT11: 170,799; GT12: 171,078; ST10: 170,939.
Total starts for each gas turbine at TG2 since commercial operation, up to 27th February 2023: GT11: 1,712; GT12: 1,429; ST10: 196.
Hours since major maintenance and inspection in 2021: GT1: 8,944 EOH; GT2: 8,328 EOH; STG: approximately 8,900 EOH.