GE, LM2500-PE-MD, Gas Turbine Generator Sets, 2 Units, Natural Gas, Woodward MicroNet Controls

Description

  1. Overview
    1. Only run about 8000 hours with another 16000 hours remaining.
    2. Each set of gas turbine packing includes: air inlet housing, gas turbine, acc gear, load gear, exhaust plenum, turbine control device, on base auxiliary components, generator, lg compartment, water wash skid, fuel forwarding skid, control compartment, mv frame and cell, electrical system mcc, battery and charger, 52g compartment including bleeding transformer, generator protection and excitation, fuel gas final metering skid, steam injection skid and water injection skid.
  2. General Data
    1. Engine model: 7LM2500-PE-MD
    2. Power turbine model: GE 6-pack
    3. Type of fuel: natural gas
    4. Type of nox suppression: none
  3. Service Dates
    1. Date unit out of service: 15-03-2021
    2. Date unit into service: 04-02-2022
    3. Last inspection date: 13-02-2020
  4. Engine Timers
    1. Total fired hours: unknown
    2. Time since last inspection: 9224 hours
    3. Time since last hso: 0 hours
    4. Time since last moh: 28702 hours
    5. Total fired starts: 92 starts
    6. Total starts since last inspection: 21 starts
    7. Total starts since last hso: 0 starts
    8. Total starts since last moh: 92 starts
    9. Total emergency trips: unknown
    10. Reason for last shop visit: hso
  5. Controls Main Component Equipment List
    1. Turbine control panel: Woodward Micronet
    2. Installed cpu: unknown
    3. Remote 1/0 system: n/a
    4. Fire-fighting / safety system: Fire Lite Alarms Inc-MS-9200
    5. Running scada application (incl. version): iFix 5.8
    6. Vibrations monitor: Bently Nevada 3500
    7. Overspeed monitor: Jacquet switch
  6. Condition
    1. Not rebuilt.
  7. Specifications
    1. Engine serial number: 481-415
    2. Power turbine serial number: 481-863