GE, Frame 9E, 2009, 124 MW, 50 Hz, Simple Cycle Gas Turbine Package

Description

  1. Overview
    1. Gas turbine model/type: General Electric GE Frame 9E - PG9171(E) 50Hz
    2. Design output: 124 MW
    3. Design heat rate: Net heat rate at generator terminals 10,716 kJ/kWh
    4. Dln system: DLN1
    5. Commissioning date: 2009
    6. Shut-down date: 2017
    7. Total fired hours: 56,500
    8. Fired starts: 120 to 130
  2. Generator Specifications
    1. Rated output/terminal voltage: 150 MVA – 15 kV
    2. Generator: Brush
  3. Maintenance History
    1. Planned maintenance date: 2012 hot gas path inspection
    2. Planned maintenance date: 2015 major inspection
    3. Full bankable inspection performed in November 2023
  4. Auxiliary Equipment
    1. Lubricating system
    2. Air processing unit
    3. Cooling water system
    4. Starting means system
    5. Gas fuel system
    6. Fire protection system
    7. Inlet bleed heating system
    8. Hydraulic supply system
    9. Ventilation system
    10. Compressor washing system
  5. Current Condition
    1. In excellent condition as of end of 2023
    2. Under power and well preserved under OEM guidelines
    3. Borescope reports are available for qualified buyers
    4. Inspection is available
    5. Unit is still installed and preserved per OEM guidelines
    6. Does not require any major maintenance work
    7. Can be reused at the new site until the next planned maintenance
    8. Still on foundation, not dismantled