Complete 2 x Siemens SGT-400 combined-cycle cogeneration (CHP) plant, 37.4 MW gross output, 50 Hz, natural gas, complete power island and balance of plant.
Offer basis: supply only, ex-works. Used equipment, as-is/where-is, subject to inspection, documentation review and final sales and purchase agreement.
Gross output: 37.4 MW.
Combined-cycle efficiency: 46%.
Natural-gas configuration: 50 Hz.
Plant Overview
A complete matched cogeneration power island comprising two Siemens SGT-400 gas-turbine generator sets, two HRSGs, two extraction-condensing steam turbines, one supplementary gas-fired package boiler, and the principal electrical, fuel-gas, cooling-water, water-treatment, fire-protection and DCS balance-of-plant systems required for operation.
Gas turbines: 2 x Siemens SGT-400, single-shaft, low-NOx.
GT gross output: 14.034 MW each / 28.1 MW total.
Steam turbines: 2 x C4.78 extraction-condensing steam turbines.
ST output: 4.681 MW each condensing / 9.4 MW total.
Fuel-gas system: natural-gas pretreatment skid, filtration, metering, pressure regulation/heating, chromatograph and booster compressors; GT fuel demand stated at approx. 8,100 Nm3/h for both GTs.
Cooling-water system: mechanical-draft wet-recirculating cooling tower system with circulating-water pumps, cooling towers, travelling screens and forebay sump pump.
Electrical systems: 110 kV double-busbar GIS; 2 x 25 MVA main transformers; 10 kV vacuum switchgear; station-service transformers; LV PCC/MCC; UPS and 220 V DC systems.
Water treatment: ultrafiltration, two-stage RO and EDI train with demineralised-water storage, chemical dosing and membrane cleaning systems.
Fire / auxiliary systems: fire-water pumps, hydrants, extinguishers, compressed air, lube-oil systems, boiler waste-heat hot-water systems and plant lifting facilities.
Control and instrumentation: redundant DCS / MIS architecture with operator/engineering/history stations, redundant controllers, industrial ethernet, firewalls and isolation gateways.
Scope of Supply - Included
Complete power island: 2 x SGT-400 GT and generators.
2 x HRSG.
2 x C4.78 steam turbines and generators.
Supplementary SZS20 gas-fired package boiler.
Fuel-gas pretreatment skid and booster compressors.